ISOLATED DC/DC CONVERTERS
48 Vdc Input 12 Vdc/12 A, 3.3 Vdc/46 A, 5 Vdc/30 A, 1.2-2.5 Vdc/50 A Outputs
May 17, 2011
Bel Power Inc., a subsidiary of Bel Fuse Inc.
General Specifications
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
VO=12 V
90
89
88
87
85
82
80
93
92.5
91
90.5
88
-
-
-
-
-
-
-
%
%
%
%
%
%
%
VO=5.0 V
VO=3.3 V
VO=2.5 V
VO=1.8 V
VO=1.5 V
VO=1.2 V
Vin=48V, full load
85
83
Switching Frequency
Isolation capacitance
280
-
330
380
-
kHz
pF
1500
Input to Output Isolation Voltage
-
-
2000
V
The total voltage increased by trim
and remote sense should not exceed
10%Vo.
Remote Sense Compesation
Output Voltage Trim Range
Over Temperature Protection
Over Voltage Protection
-
80
-
-
10
% Vo
% Vo
C
-
110
125
130
-
-
-
% Vo Vin=48V, full load, Hiccup mode
Calculated Per Bell Core SR-332 (IO
=80% load, Vin=48 V, Vo=3.3 V; Ta =
MTBF
1,109,917
Hours
25 C)
Dimensions
Inches (L × W × H)
-
2.30 x 1.45 x 0.395
Millimeters (L × W × H)
58.42 x 36.83 x 10.03
Weight
-
41
-
g
Note: All specifications are typical at nominal input, full load at 25 C unless noted.
Remote On/Off
Parameter
Min
Typ
Max
Unit
Notes
Signal Low (Unit On)
-0.3
-
0.8
V
0RQB-C5TxxL.
The remote on/off pin open, Unit off.
Active Low
Active High
Signal High (Unit Off)
Signal Low (Unit Off)
Signal High (Unit On)
Current Sink
2.4
-0.3
2.4
0
-
-
-
-
18
0.8
18
V
V
0RQB-C5Txx0.
The remote on/off pin open, Unit on.
V
0.75
mA
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com