ZT-SERIES
Triple output 30W ~ 170W
Ⅵ Model name
ZT 30-522
ZT90
ZT170
522: 5V, +12V, –12V
5FF: 5V, +15V, –15V
525: 5V, +12V, –5V
Output voltage code
Name of series Output power: 4 types
in 30W ~ 170W
Ⅵ Features
ⅷ
ⅷ
marking (Low Voltage Directive)
Triple output
12 models, 30W, 60W, 90W, 170W
Wide input voltage range:
100/200VAC user selectable
ⅷ
ZT60
ZT30
ⅷ Isolation between CH1 (5V) and ±CH
ⅷ Compact, low profile and board type
ⅷ 1 year warranty
(Low Voltage Directive)
1 year warranty
Ⅵ Specifications
1. Input voltage range 85 ~ 132VAC /170 ~ 265VAC (47 ~ 63Hz), 230 ~ 330VDC user selectable
2. Output voltage
range
CH1: +5V (5.0 ~ 5.25V), CH2: Fixed, CH3: Fixed
3. Cooling
Convection cooling
4. Operating ambient –10 ~ +60°C
temperature
ZT30, 60, 90 Output derating –10 ~ +50°C: 100%, +60°C: 70%
(Standard mounting) ZT170: Forced air cooling –10 ~ +50°C: 100%, +60°C: 70% (0.7m/S)
ZT170: Convection cooling
CH1 ··· –10 ~ +25°C: 15A, +30°C: 13A, +40°C: 12A, +50°C: 10A, +60°C: 8A
CH2, CH3 ··· –10 ~ +50°C: 100%, +60°C: 70%
5. Withstand voltage
6. Safety standard
7. EMI
Input-output: 3.75kVAC, Input-chassis: 2.5kVAC one minute each
Approved by UL1950 , CSA950 and EN60950
Conforms to VCCI-class B, FCC class B and VDE class B
Over voltage protection (CH1), Over current protection
8. Functions
Ⅵ Product lineup
Note 1
Note 1
Nominal
Min.
Max.
Max. output Total max.
Nominal
Min.
Max.
Max. output Total max.
Model name
CH
UL CSA EN
Model name
CH
UL CSA EN
output power
output voltage
output current output current power
output power
output voltage
output current output current power
CH1 5V
0.3A 3.0A 15.0W 33.0W
1.2A
⅜
⅜
⅜
⅜
⅜
⅜
CH1 5V
1A 10.0A 50.0W 92.0W
3.0A
⅜
⅜
⅜
ZT30-522 CH2 +12V
0A
14.4W 33.0W
ZT90-522 CH2 +12V
0A
36.0W 92.0W
⅜
⅜
⅜
(2.0A)
(4A)
CH3 –12V
CH1 5V
0A
0.3A 3.6W 33.0W
⅜
⅜
⅜
⅜
⅜
⅜
CH3 –12V
CH1 5V
0A
0.5A 6.0W 92.0W
⅜
⅜
⅜
⅜
⅜
⅜
0.3A 3.0A 15.0W 34.5W
1.0A
1A 10.0A 50.0W 92.0W
2.5A
ZT30 ZT30-5FF CH2 +15V
0A
15.0W 34.5W
⅜
⅜
⅜
ZT90 ZT90-5FF CH2 +15V
0A
37.5W 95.0W
⅜
⅜
⅜
(2.0A)
(4A)
CH3 –15V
CH1 5V
0A
0.3A 4.5W 34.5W
⅜
⅜
⅜
⅜
⅜
⅜
CH3 –15V
CH1 5V
0A
0.5A 7.5W 95.0W
⅜
⅜
⅜
⅜
⅜
⅜
0.3A 3.0A 15.0W 30.9W
1.2A
1A 10.0A 50.0W 88.5W
3.0A
ZT30-525 CH2 +12V
0A
14.4W 30.9W
⅜
⅜
⅜
ZT90-525 CH2 +12V
0A
36.0W 88.5W
⅜
⅜
⅜
(2.0A)
(4A)
CH3 –5V
CH1 5V
0A
0.3A 1.5W 30.9W
⅜
⅜
⅜
⅜
⅜
⅜
CH3 –5V
CH1 5V
0A
0.5A 2.5W 88.5W
⅜
⅜
⅜
⅜
⅜
⅜
0.5A 5.0A 25.0W 61.0W
2.5A
1A 20.0A 100.0W172.0W
5.0A
ZT60-522 CH2 +12V
0A
30.0W 61.0W
⅜
⅜
⅜
ZT170-522 CH2 +12V
0A
60.0W 172.0W
⅜
⅜
⅜
(3.5A)
(6A)
CH3 –12V
CH1 5V
0A
0.5A 6.0W 61.0W
⅜
⅜
⅜
⅜
⅜
⅜
CH3 –12V
CH1 5V
0A
1.0A 12.0W 172.0W
⅜
⅜
⅜
⅜
⅜
⅜
0.5A 5.0A 25.0W 62.5W
2.0A
1A 20.0A 100.0W175.0W
4.0A
ZT60 ZT60-5FF CH2 +15V
0A
30.0W 62.5W
⅜
⅜
⅜
ZT170 ZT170-5FF CH2 +15V
0A
60.0W 175.0W
⅜
⅜
⅜
(3.5A)
(6A)
CH3 –15V
CH1 5V
0A
0.5A 7.5W 62.5W
⅜
⅜
⅜
⅜
⅜
⅜
CH3 –15V
CH1 5V
0A
1.0A 15.0W 175.0W
⅜
⅜
⅜
⅜
⅜
⅜
0.5A 5.0A 25.0W 57.5W
2.5A
1A 20.0A 100.0W165.0W
5.0A
ZT60-525 CH2 +12V
CH3 –5V
0A
30.0W 57.5W
⅜
⅜
⅜
⅜
⅜
⅜
ZT170-525 CH2 +12V
CH3 –5V
0A
0A
60.0W 165.0W
⅜
⅜
⅜
(3.5A)
(6A)
0A
0.5A 2.5W 57.5W
1.0A 5.0W 165.0
W
⅜
⅜
⅜
Note 1: Duration of peak current shown in ( ): 5 seconds max.
⅜ : Safety standard approved
ⅷ Request customer specification for further details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
ⅷ Contact us about delivery before ordering.