5秒后页面跳转
Z01H55 PDF预览

Z01H55

更新时间: 2024-01-24 20:27:28
品牌 Logo 应用领域
欧姆龙 - OMRON 开关
页数 文件大小 规格书
28页 5911K
描述
General-purpose Basic Switch

Z01H55 数据手册

 浏览型号Z01H55的Datasheet PDF文件第21页浏览型号Z01H55的Datasheet PDF文件第22页浏览型号Z01H55的Datasheet PDF文件第23页浏览型号Z01H55的Datasheet PDF文件第25页浏览型号Z01H55的Datasheet PDF文件第26页浏览型号Z01H55的Datasheet PDF文件第27页 
Tightening  
Micro Load Applicable Range  
The suitable tightening torque for screw terminals is given below.  
Using a model for ordinary loads to open or close the contact of a  
micro load circuit may result in faulty contact. Use models that  
operate in the following range. However, even when using micro load  
models within the operating range shown here, if inrush current  
occurs when the contact is opened or closed, it may increase contact  
wear and so decrease durability. Therefore, insert a contact  
protection circuit where necessary.  
Screw terminals except for those on Split-contact Models  
(Z-10FY-B): 0.78 to 1.18 N·m  
Screw terminals on Split-contact Models  
(Z-10FY-B): 0.49 to 1.18 N·m  
Operation  
The minimum applicable load is the N-level reference value. This  
value indicates the malfunction reference level for the reliability level  
of 60% (λ60). The equation, λ60 = 0.5×10-6/operations indicates that  
the estimated malfunction rate is less than 1/2,000,000 operations  
with a reliability level of 60%.  
Make sure that the switching speed and frequency are is within the  
specified ranges.  
1. If the switching speed is extremely slow, the contacts may not be  
switched smoothly, which may result in a contact failure or contact  
welding.  
2. If the switching speed is extremely fast, switching shock may  
damage the Switch prematurely. If the switching frequency is too  
high, the contacts may not be able to keep up with the speed.  
5 mW  
800 mW  
0.16 mA  
26 mA  
30  
24  
Operating  
range for  
general load  
models  
The rated permissible switching speed and frequency indicate the  
switching reliability of the Switch.  
The life of a Switch is determined at the specified switching  
speed. The life varies with the switching speed and frequency  
even when they are within the permissible ranges.  
Z-15H, H2  
Z-15G  
Z-15E  
Z-10FY  
Z-15ER  
Operating range  
for micro load  
models Z-01H  
Always conduct appropriate durability tests under actual condi-  
tions before using a Switch.  
Make sure that the actuator travel does not exceed the permissible  
OT position. The operating stroke must be set to 70% to 100% of  
the rated OT.  
12  
Unusable  
range  
5
0
1 mA  
100 mA 160 mA  
Panel Mount Switch (Z-15@Q@, Z-01@Q@)  
0.1  
1
10  
100  
1,000  
Current (mA)  
When mounting the panel mount plunger model with screws on a  
side surface, be careful of the dog angle and operation speed.  
Excessive dog angle or operation speed may damage the Switch.  
When using the panel mount plunger model mounted with screws  
on a side surface, be careful not to apply a large shock. Applying a  
shock exceeding 1,000 m/s2 may damage the Switch.  
Z-01H  
Z-15@, Z-10FY  
160 mA at 5 VDC  
Minimum applicable load  
1 mA at 5 VDC  
Models with Drip-proof Terminal Cover (Z-  
@
A55-B5V) Wiring  
When using the panel mount plunger model mounted with screws  
on a side surface, remove the hexagonal nuts from the actuator.  
To attach the Protective Cover to the case, hold the cover in almost  
parallel to the case and then push it to the case. If the cover is  
pushed diagonally, the rubber packing may slip off, degrading the  
sealability of the Switch.  
High-sensitivity Switch (Z-15H)/  
Extra-high-sensitivity Switch (Z-15H2)  
When using the Switch in a DC circuit, be sure to provide an arc  
suppressor as well because the small contact gap of the Switch  
may result in contact troubles.  
Terminal with  
toothed  
washer  
In an application where a high repeat accuracy is required, limit the  
current that flows through the Switch to within 0.1 A. Also, use a  
relay to control a high-capacity load if the Switch is connected to  
such a load. (In this case, the exciting current of the relay coil is the  
load of the Switch.)  
Rubber packing  
Do not apply a force of 19.6 N or higher to the pin plunger.  
Exercise care that the environment conditions such as temperature  
and humidity do not change abruptly.  
Use round solderless terminals having the following dimensions to  
connect leads to the terminals. Tighten the screws of terminals to a  
torque of 0.78 to 1.18 N·m. Use the terminal shown below.  
4.3 dia.  
8
20 max.  
A cable 8.5 to 10.5 mm in diameter can be applicable to the sealing  
rubber of the lead outlet of the Switch. A two-core or three-core  
VCT cable having a cross-sectional area of 1.25 mm2 is especially  
suitable for this.  
M4 small screws with spring toothed washer are used as the termi-  
nal screws.  
170  
General-purpose Basic Switch Z  

与Z01H55相关器件

型号 品牌 获取价格 描述 数据表
Z-01H55 OMRON

获取价格

General-purpose Basic Switch
Z-01H55-B OMRON

获取价格

General-purpose Basic Switch
Z01HB OMRON

获取价格

General-purpose Basic Switch
Z-01H-B OMRON

获取价格

General-purpose Basic Switch
Z-01HD OMRON

获取价格

General-purpose Basic Switch
Z-01HD55 OMRON

获取价格

General-purpose Basic Switch
Z-01HD55-B OMRON

获取价格

General-purpose Basic Switch
Z-01HDA55 OMRON

获取价格

Snap Acting/Limit Switch,
Z-01HDA55-B OMRON

获取价格

Snap Acting/Limit Switch,
Z01HDB OMRON

获取价格