VI-200, VE-200
CONVERTER SPECIFICATIONS (cont.)
OUTPUT CHARACTERISTICS
VI-200 E-Grade
VI-200 C-, I-, M-Grade
Parameter
Min
Typ
Max
2%
Min
Typ
0.5%
0.05%
0.2%
0.01
Max
Units
VNOM
VNOM
Test Conditions
Setpoint accuracy
Load/line regulation
Load/line regulation
Output temperature drift
Long term drift
1%
1%
0.5%
1%
0.2%
0.5%
0.02
LL to HL, 10% to Full Load
LL to HL, No Load to 10%
Over rated temp.
V
NOM
0.02
0.02
% / °C
0.02
%/1K hours
Output ripple – pp:
2 V, 3.3 V
150
5%
3%
60
2%
100
3%
mV
20 MHz bandwidth
20 MHz bandwidth
20 MHz bandwidth
5 V
VNOM
VNOM
10 – 95 V
0.75%
1.5%
Trim range[a]
50%
0.5
110%
50%
0.5
110%
VNOM
Total remote
sense compensation
Volts
0.25 V max. neg. leg
OVP set point
125%[b]
115%
105%
20%
125%[b]
135%
125%
130%
VNOM
Ifull load
Ifull load
Recycle power
Current limit
105%
20%
135%
140%
Automatic restart
Automatic restart
Short circuit current[c]
[a]
10 V, 12 V, 13.8 V, 15 V outputs, or “V” input range have standard trim range 10%. Consult factory for wider trim range.
3.3 V output trim range 2.20 to 3.63 V, 95 V output –50 + 0% trim range.
131% nominal for booster modules.
[b]
[c]
Output voltages of 3.3 V or 5 V incorporate foldback current limiting; For output voltages from 5.2 V to 7.5 V consult factory; All other outputs provide constant current limiting.
CONTROL PIN SPECIFICATIONS
VI-200 E-Grade
Typ
VI-200 C-, I-, M-Grade
Parameter
Min
Max
Min
Typ
Max
Units
Ohms
Ohms
Volts
Volts
mA
Test Conditions
Gate out impedance
Gate in impedance
50
1000
6
50
1000
6
Gate in open circuit voltage
Gate in low threshold
Gate in low current
Use open collector
0.65
0.95
0.65
0.95
6
6
Power sharing accuracy
1.05
1.05
VI-200 DC-DC Converters
Page 3 of 6
Rev 3.6
vicorpower.com
800 927.9474
08/2014