CONTROL FUNCTIONS - PC PIN  
Module Enable/Disable  
Module Alarm  
The module may be disabled by pulling PC below 2.3 V with  
respect to the –Input. This may be done with an open collector  
transistor, relay, or optocoupler. Multiple converters may be  
disabled with a single transistor or relay either directly or via  
“OR’ing” diodes. See Figure 1.  
The module contains “watchdog” circuitry which monitors  
input voltage, operating temperature and internal operating  
parameters. In the event that any of these parameters are  
outside of their allowable operating range, the module will  
shut down and PC will go low. PC will periodically go high  
and the module will check to see if the fault (as an example,  
overtemperature) has cleared. If the fault has not been cleared,  
PC will go low again and the cycle will restart. The SC pin  
will go low in the event of a fault and return to its normal  
state after the fault has been cleared. See Figures 2 and 4.  
Primary Auxiliary Supply  
At 5.7 V, PC can source up to 1.5 mA. In the example shown  
in Figure 3, PC powers a module enabled LED.  
Input Undervoltage  
Input Overvoltage (See Note 1)  
+OUT  
+IN  
PC  
Overtemperature  
Module Faults  
Auto  
+In  
PC  
+Out  
Restart  
SW1  
+S  
SC  
–S  
2-20 ms typ.  
50 Ω  
+S  
SC  
–S  
f (V  
IN  
)
SW1, 2, & 3  
shown in  
1 K  
6 K  
SW2  
SW3  
1 M  
PR  
"Fault" position  
Disable  
PR  
–In  
5.7 Vdc  
–IN  
(0-3 mA)  
1.23  
Vdc  
– OUT  
–Out  
Disable = PC <2.3V  
1
Not applicable for 300 Vdc input family  
Figure 1 Module enable/disable.  
Figure 2 PC/SC module alarm logic.  
+In  
+Out  
Fault  
PC  
40 μs typ.  
5.7 V  
PC  
+S  
SC  
–S  
4kΩ  
"Module  
PR  
–In  
Enabled"  
1.23 V  
2–20 ms typical  
SC  
–Out  
Figure 3 LED on-state indicator.  
Figure 4 PC/SC module alarm timing.  
Optocoupler  
+In  
PC  
+In  
PC  
+Out  
+Out  
+S  
SC  
–S  
+S  
SC  
–S  
4 kΩ  
Alarm  
PR  
–In  
PR  
–In  
1.00V  
–Out  
–Out  
Figure 5 Isolated on-state indicator.  
Figure 6 Secondary side on-state indicator.  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
48V Mini Family  
Rev. 7.4a  
Page 6 of 11  
Set your site on VICOR at vicorpower.com  

与V48B3V3C100B3相关器件

型号 品牌 获取价格 描述 数据表
V48B3V3C100BF VICOR

获取价格

DC-DC Regulated Power Supply Module
V48B3V3C100BN3 VICOR

获取价格

DC-DC Regulated Power Supply Module
V48B3V3C100BS VICOR

获取价格

DC-DC Regulated Power Supply Module
V48B3V3C150AL VICOR

获取价格

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid
V48B3V3C150AL2 VICOR

获取价格

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid
V48B3V3C150AL3 VICOR

获取价格

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid
V48B3V3C150AN2 VICOR

获取价格

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid
V48B3V3C150B VICOR

获取价格

48Vin / 3.3Vout / 150Watts DC-DC Converter Module
V48B3V3C150B2 VICOR

获取价格

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid, PACKAGE-9
V48B3V3C150B3 VICOR

获取价格

CONVERTER MOD DC/DC 3.3V 150W