MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
8 Vout, 200 W (e.g. V375B8C200BL)
Parameter
Min
Typ
84.2
320
9.7
Max
Unit
%
Notes
Efficiency
83
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
400
10.1
6.9
mV
9.36
Volts
Watts
%
6
0.02
0.2
No load to full load; nominal input
0
25
Amps
Amps
Amps
Current limit
25.5
17.5
28.8
28.8
33.8
33.8
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
12 Vout, 300 W (e.g. V375B12C300BL)
Parameter
Min
Typ
86.6
150
14.3
6
Max
Unit
%
Notes
Efficiency
84.3
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
188
14.9
9
mV
13.7
Volts
Watts
%
0.02
0.3
25
No load to full load; nominal input
0
Amps
Amps
Amps
Current limit
25.5
17.5
28.8
28.8
35
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
35
12 Vout, 200 W (e.g. V375B12C200BL)
Parameter
Min
Typ
85.4
258
14.3
8.5
Max
Unit
%
Notes
Efficiency
84
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
323
14.9
10
mV
13.7
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
16.67
22.6
22.6
Amps
Amps
Amps
Current limit
17
19.2
19.2
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
11.6
15 Vout, 300 W (e.g. V375B15C300BL)
Parameter
Min
Typ
87.5
140
17.8
5.6
Max
Unit
%
Notes
Efficiency
85
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
175
18.5
8.4
0.3
20
mV
17.1
Volts
Watts
%
0.02
No load to full load; nominal input
0
Amps
Amps
Amps
Current limit
20.4
14
23
23
26
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
26
15 Vout, 200 W (e.g. V375B15C200BL)
Parameter
Min
Typ
87.7
222
17.8
7.7
Max
Unit
%
Notes
Efficiency
86.5
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
278
18.5
9
mV
17.1
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
13.33
18
Amps
Amps
Amps
Current limit
13.5
9.31
15.3
15.3
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
18
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
375V Mini Family
Rev. 8.4
Page 5 of 13
Set your site on VICOR at vicorpower.com