MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
28 Vout, 150 W (e.g. V24C28C150BL)
Parameter
Min
Typ
88.0
100
32.7
4.2
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Efficiency
86.0
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
150
33.8
6.2
0.2
5.4
7.2
7.2
31.6
0.02
No load to full load; nominal input
0
5.5
3.8
Current limit
Short circuit current
6.2
6.2
Output voltage 95% of nominal
Output voltage <250 mV
28 Vout, 100 W (e.g. V24C28C100BL)
Parameter
Min
Typ
89
85
32.7
3.3
0.02
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Efficiency
88
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
107
33.9
5
0.2
3.57
5
31.5
No load to full load; nominal input
0
3.64
0.5
Current limit
Short circuit current
4.12
4.12
Output voltage 95% of nominal
Output voltage <250 mV
5
28 Vout, 50 W (e.g. V24C28C50BL)
Parameter
Min
Typ
89
80
32.7
1.8
0.02
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Efficiency
87.5
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
100
33.9
2.7
31.5
0.2
No load to full load; nominal input
0
1.82
1.25
1.78
2.42
2.42
Current limit
Short circuit current
2.06
2.06
Output voltage 95% of nominal
Output voltage <250mV
36 Vout, 100 W (e.g. V24C36C100BL)
Parameter
Min
Typ
87.1
32
41.9
3.7
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Efficiency
86
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
40
43.4
4.3
40.4
0.02
0.2
No load to full load; nominal input
0
2.83
1.94
2.78
3.76
3.76
Current limit
Short circuit current
3.2
3.2
Output voltage 95% of nominal
Output voltage <250 mV
36 Vout, 50 W (e.g. V24C36C50BL)
Parameter
Min
Typ
84.9
27
41.9
1.8
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Efficiency
84
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
34
43.4
2.3
40.4
0.02
0.2
No load to full load; nominal input
0
1.41
0.97
1.39
1.88
1.88
Current limit
Short circuit current
1.6
1.6
Output voltage 95% of nominal
Output voltage <250 mV
Vicor Corp.
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
24V Micro Family
Rev. 5.0
Page 7 of 14
Set your site on VICOR at vicorpower.com