MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
48 Vout, 400 W (e.g. V24A48C400BL)
Parameter
Min
Typ
86.7
160
Max
Unit
%
Notes
Efficiency
84.7
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwith
25°C; recycle input voltage to restart (1 minute off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
200
57.8
12.7
0.2
mV
53.8
55.8
11.8
0.02
Volts
Watts
%
No load to full load; nominal input
0
8.33
11.3
11.3
Amps
Amps
Amps
Current limit
8.49
4.79
9.58
9.58
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
48 Vout, 300 W (e.g. V24A48C300BL)
Parameter
Min
Typ
87.1
180
55.7
7.7
Max
Unit
%
Notes
Efficiency
86
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwith
25°C; recycle input voltage to restart (1 minute off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
225
57.7
10
mV
53.7
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
6.25
8.44
8.44
Amps
Amps
Amps
Current limit
6.37
4.37
7.19
7.19
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
24V Maxi Family
Rev. 3.8
Page 7 of 13
Set your site on VICOR at www.vicorpower.com