描述
民用设备,工业设备

ULE-1.5/20-D48PM 技术参数

是否Rohs认证: 符合生命周期:Obsolete
零件包装代码:MODULE包装说明:,
针数:8Reach Compliance Code:unknown
ECCN代码:EAR99风险等级:5.74
Is Samacsys:N模拟集成电路 - 其他类型:DC-DC REGULATED POWER SUPPLY MODULE
最大输入电压:75 V最小输入电压:36 V
标称输入电压:48 VJESD-30 代码:R-XDMA-T8
JESD-609代码:e4最大负载调整率:0.25%
功能数量:1输出次数:1
端子数量:8最大输出电压:1.32 V
最小输出电压:0.96 V标称输出电压:1.2 V
封装主体材料:UNSPECIFIED封装形状:RECTANGULAR
封装形式:MICROELECTRONIC ASSEMBLY峰值回流温度(摄氏度):NOT SPECIFIED
认证状态:Not Qualified表面贴装:NO
技术:HYBRID端子面层:GOLD OVER NICKEL
端子形式:THROUGH-HOLE端子位置:DUAL
处于峰值回流温度下的最长时间:NOT SPECIFIED最大总功率输出:36 W
微调/可调输出:YESBase Number Matches:1

ULE-1.5/20-D48PM 数据手册

 浏览型号ULE-1.5/20-D48PM的Datasheet PDF文件第2页浏览型号ULE-1.5/20-D48PM的Datasheet PDF文件第3页浏览型号ULE-1.5/20-D48PM的Datasheet PDF文件第4页浏览型号ULE-1.5/20-D48PM的Datasheet PDF文件第6页浏览型号ULE-1.5/20-D48PM的Datasheet PDF文件第7页浏览型号ULE-1.5/20-D48PM的Datasheet PDF文件第8页 
ULE Series  
Isolated, High Density, Eighth-Brick  
1.25–30 Amp, DC/DC Converters  
PERFORMANCE SPECIFICATION NOTES  
1. All models are tested and specified with external 1||10 μF ceramic/tantalum output  
capacitors and a 22 μF external input capacitor. All capacitors are low ESR types.  
These capacitors are necessary to accommodate our test equipment and may  
not be required to achieve specified performance in your applications. All models  
are stable and regulate within spec under no-load conditions. General conditions  
for Specifications are +25 deg.C, VIN=nominal, VOUT=nominal, full load. Adequate  
airflow must be supplied for extended testing under power.  
2. Input Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input  
filtering is CIN=33 μF tantalum, CBUS=220 μF electrolytic, LBUS=12 μH.  
3. Note that Maximum Power Derating curves indicate an average current at nominal  
input voltage. At higher temperatures and/or lower airflow, the DC/DC converter will  
tolerate brief full current outputs if the total RMS current over time does not exceed  
the Derating curve. All Derating curves are presented at sea level altitude. Be aware  
of reduced power dissipation with increasing density altitude.  
4. Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1,  
Case 3, ground fixed conditions, Tpcboard=+25ºC, full output load, natural air convection.  
5. The On/Off Control is normally controlled by a switch. But it may also be driven with  
external logic or by applying appropriate external voltages which are referenced to  
Input Common. The On/Off Control Input should use either an open collector or open  
drain transistor.  
9. All models are fully operational and meet published specifications, including “cold  
start” at –40ºC.  
10. Regulation specifications describe the deviation as the line input voltage or output  
load current is varied from a nominal midpoint value to either extreme.  
11. Alternate pin length and/or other output voltages are available under special quantity  
order.  
12. Electronic overvoltage shutdown is not included on 48V input models to comply  
with certain telecom reliability requirements. These requirements attempt continued  
operation despite input overvoltage. The converter is rated only to the maximum  
input voltage.  
13. Do not exceed maximum power specifications when adjusting the output trim.  
14. At zero output current, the output may contain low frequency components which  
exceed the ripple specification. The output may be operated indefinitely with no load.  
15. If reverse polarity is accidentally applied to the input, a body diode will become  
forward biased and will conduct considerable current. To ensure reverse input  
protection with full output load, always connect an external input fuse in series with  
the +VIN input. Use approximately twice the full input current rating with nominal  
input voltage.  
16. Output current limit is non-latching. When the overcurrent fault is removed, the  
converter will immediately recover.  
17. The Sense inputs are not included on 12V, 24V & 48V input models.  
18. ULE-12/4.2-D24 minimum load is 0.42 Amps (10%) for rated specifications.  
19. ULE-5/12-D24 IOUT=8A max. if VIN=19-20V.  
6. Short circuit shutdown begins when the output voltage degrades approximately 2%  
from the selected setting.  
7. The outputs are not intended to sink appreciable reverse current..  
8. Output noise may be further reduced by adding an external filter. See I/O Filtering  
and Noise Reduction.  
20. ULE-12/4.2-D48 has no surface mount option.  
21. Full load conditions, see ordering guide.  
PHYSICAL CHARACTERISTICS AND SAFETY  
Outline dimensions  
See mechanical specs (below)  
Copper alloy  
Pin material  
Pin diameter  
Pin finish  
0.04/0.062" (1.016/1.524mm)  
Nickel underplate with gold overplate  
1 ounce (28 grams)  
Weight  
Electromagnetic interference (conducted and radiated)  
(external filter required)  
Safety  
Designed to meet FCC part 15, class B, EN55022  
Designed to meet UL/cUL 60950-1, CSA-C22.2 No. 60950-1, IEC/EN 60950-1  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_ULE Series.C11 Page 5 of 23  

与ULE-1.5/20-D48PM相关器件

型号 品牌 描述 获取价格 数据表
ULE-1.5/20-D48PM-C MURATA 民用设备,工业设备

获取价格

ULE-1.8/20-D24N-C MURATA 民用设备,工业设备

获取价格

ULE-1.8/20-D24NM-C MURATA 民用设备,工业设备

获取价格

ULE-1.8/20-D24NML2-C MURATA DC-DC Regulated Power Supply Module, 1 Output, 36W, Hybrid, ROHS COMPLIANT, EIGHTH-BRICK,

获取价格

ULE-1.8/20-D24P-C MURATA Isolated, High Density, Eighth-Brick

获取价格

ULE-1.8/20-D24PL2-C MURATA DC-DC Regulated Power Supply Module, 1 Output, 36W, Hybrid, EIGHTH-BRICK PACKAGE-8

获取价格