Input Specifications  
Parameter  
Operating Range  
Inrush Current Limiting  
Thermistor  
Conditions  
Min  
90  
Typ  
Max  
264  
Units  
47-63 Hz  
VAC  
120 VAC, cold start  
240VAC, cold start  
264VAC  
30  
60  
APK  
APK  
APK  
%
Active Current Limit  
Efficiency  
19  
75  
Nominal line and full load  
Power Factor Correction (PFC)  
0.99  
Meets IEC 1000-4-7/EN61000-3-2 (formerly IEC 555-2)  
Power Fail Signal  
Remote Sense  
Upon AC input voltage removal, the power fail signal drops  
to logic zero at least 10msec before loss of DC output.  
Upon AC input turn-on, signal remains low until output is in  
regulation. Consult the factory for other options.  
Remote Sense is provided and will compensate for 1.0V  
of line drop. Remote Sense leads are protected against  
open, short and reversal.  
Remote On/Off (Optional)  
N+1 Load Share  
Output has active load sharing circuitry. Units will load  
share within 1% of the Maximum Rated Load.  
The power supply is turned on with aTTL logic1(or open)  
signal and turned off by a switch closure or TTL logic ‘0’  
referenced to (-) sense terminal. Consult the factory for  
other options.  
Over Temperature Protection  
Thermal switch turns off power supply if overheating occurs  
and automatically restarts.  
Over Voltage Protection  
Output #1: 15% of nominal voltage is typical.  
The power supply will latch off until AC power is cycled.  
Safety  
UL Recognized: UL File Number E13164 (1950)  
CSA Certified: CSA File Number LR 9070C  
(C22.2 No950, Level 6)  
Over Current Protection  
Automatic recovery upon fault removal.  
TUV License Number: R9773309 (EN60950) (IEC950)  
Transient Response  
The peak output voltage excursion will not exceed 2% and  
will recover within 1% in 200 μsec for a 25% step load.  
Cooling  
The unit is designed to operate with 30 CFM of airflow.  
Reverse Voltage Protection  
DC Power Good Signal  
The output is protected to rated load.  
The signal is activated by a ±10% loss of regulation Active  
low or high;TTL Level; common with (-) sense. Consult the  
factory for other options.  
Page 2  
SX400 2/98 REV A  

与TPS_SX400相关器件

型号 品牌 获取价格 描述 数据表
TPS_SX500 CANDD

获取价格

AC/DC POWER SUPPLY
TPS_TX1000 CANDD

获取价格

1000 Watt, Single Output, AC/DC Power Supply
TPS_TXD2000 CANDD

获取价格

AC/DC POWER SUPPLY
TPS0402 TELEDYNE

获取价格

PTC-Thickfilm Temperature Sensors
TPS0505 TOPPOWER

获取价格

2W 6KVDC Isolated Dual Output DC/DC Converters
TPS0505A TOPPOWER

获取价格

2W 6KVDC Isolated Dual Output DC/DC Converters
TPS0509 TOPPOWER

获取价格

2W 6KVDC Isolated Dual Output DC/DC Converters
TPS0509A TOPPOWER

获取价格

2W 6KVDC Isolated Dual Output DC/DC Converters
TPS0512 TOPPOWER

获取价格

2W 6KVDC Isolated Dual Output DC/DC Converters
TPS0512A TOPPOWER

获取价格

2W 6KVDC Isolated Dual Output DC/DC Converters