TPP 40 Series, 40 Watt
General Specifications
Operating temperature
–40°C to +85°C with derating, see graph on p.4
Output power derating
– Temperature
single output: 2.67 %/K above +70°C at 230 VAC
2.75 %/K above +65°C at 115 VAC
multi output: 1.60 %/K above +60°C at 230 VAC
1.67 %/K above +55°C at 115 VAC
– Low input voltage
1.33 %/V below 100 VAC
Storage temperature
–40°C to +85°C
5 – 95 % rel. H maꢀ.
5000 m
Humidity (non condensing)
Altitude during operation
Switching frequency - single output
(at 230 VAC)
Switching frequency - multi output
(at 230 VAC)
5 VDC model: 70 kHz typ. (pulse frequency modulation)
other models: 120 kHz typ. (pulse frequency modulation)
5 VDC model: 70 kHz typ. (pulse frequency modulation)
other models: 115 kHz typ. (pulse frequency modulation)
750 kHz typ. (pulse frequency modulation)
– Vout 1
– Vout 2
– Vout 3
510 kHz typ. (pulse frequency modulation)
Isolation voltage
(2 ꢀ MOPP insulation)
– Input / Output (60 s)
– Input / Case (60 s)
4000 VAC
2500 VAC
Leakage current (at 264 VAC/60Hz)
Isolation resistance (at 500 VDC)
Reliability
75 µA maꢀ.
100 MOhm min.
– calculated MTBF at +25°C acc. to IEC 61709
3‘000‘000 h for single output models
1‘700‘000 h for multi output models
Protection class
class II prepared
Electromagnetic compatibility – Conducted & Radiated input surpression
EN 55011 limits to IEC 60601-1-2 4th editon
EN 55032 class B (internal filter)
IEC / EN 61000-3-2, class B
(EMC), emissions
– Harmonic current emissions
– Voltage flicker
IEC / EN 61000-3-3, class B
Electromagnets compatibility (EMC), immunity
– Electrostatic discharge ESD
– RF field immunity
IEC / EN 60601-1-2
IEC / EN 61000-4-2, 8kV/6kV perf. criteria A
IEC / EN 61000-4-3, 20V/m perf. criteria A
IEC / EN 61000-4-4, 2kV perf. criteria A
IEC / EN 61000-4-5, 1kV/ 2kV perf. criteria A
IEC / EN 61000-4-6, 20 Vrms perf. criteria A
IEC / EN 61000-4-8, 10A/m perf. criteria A
– Electrical fast transients/burst immunity
– Surge
– Conducted RF
– Magnetic field (only for single output models)
Voltage dip and interruptions according to EN 60601-1-2
reference: 100 VAC / 50Hz
30%, 500ms perf. criteria A
60%, 100ms perf. criteria B
> 95%, 10ms perf. criteria A
> 95%, 5000ms perf. criteria B
Safety standards and certification
IEC/EN 60601-1 3rd edition,
ANSI/AAMI ES60601-1:2005(R)2012
www.tracopower.com/overview/tpp40
– Certification documents
Environment
– Vibration acc. IEC 60068-2-6
– Shock acc. IEC 60068-2-27
3 aꢀis, sine sweep, 10–55Hz, 1g, 1oct/min
3 aꢀis, 10g half sine, 11msShock
20 G (3 directions each 3 times)
Environmental compliance – Reach
www.tracopower.com/products/reach-declaration.pdf
RoHS directive 2011/65/EU
– RoHS
Connection
screw terminal
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
Page 3 of 5