SPU130 SERIES
130W Desk Top Switching Power Supplies For I.T.E.
Description:
The SPU130 series of AC/DC switching mode power
supplies provide 130 Watts of continuous output power. All
supplies are UL 94V-0 compliant, include IEC-320-C14
input for worldwide applications. All models meet FCC class
B and CISPR class B emission Limits and are designed to
comply with UL, C-UL and CE requirements. All units are
100% burned in and tested.
Features:
+
+
+
+
+
+
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Output Voltage Available From 3 VDC Thru 55 VDC
Optional Output Connectors (See appendix)
Single and Dual Output
Input Surge Current, Over Voltage and Over Load
protection
Safety Approvals :
+
One year warranty
CB
Electrical Characteristics:
Sym.
Vin Input Voltage
Fin Input Frequency
Parameter
Test Conditions
Min. Typ. Max. Unit
90
47
0
264
63
VAC
Hz
W
Wo
Vo
Io
Output Power Range
Output Voltage Range
Output Current Range
Vin=90 to 264VAC
130
See rating chart V
See rating chart A
Iil Input Current (Low Line)
Iih Input Current (High Line)
Io=Full load, Vin=115VAC
Io=Full load, Vin=230 VAC
3.2
1.7
A
A
Io=Full load, 25°c ,Cool start,
Irl Low Line Inrush Current
15
30
A
Vin=115VAC
Io=Full load, 25°c, Cool start,
Irh High Line Inrush Current
30
60
A
Vin=230VAC
Eff Efficiency
Io=Full Load, Vin=230VAC
Io=Full Load
80
0.5
3
%
%
REG-i Line Regulation
REG-o Load Regulation
OVP Over Voltage Protection
OCP Over Current Protection
Ttr Transient Response
Thold Hold-Up Time
1
5
Vin=230VAC
%
112
110
132
150
4
%
%
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=100VAC
mS
mS
S
16
Ts
Start Up Time
Io=Full Load, Vin=100VAC
0.3 1
0.5
2
1
Vrn Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
Tc Temperature Coefficient All output
Optional
%
0.5 0.75
0.04
mA
%/°c
-0.04
0.3
PFC Power Factor Correction
0.99
Environmental :
Sym.
Toper Operating Temperature
Tstg Storage Temperature
Parameter
Test Conditions
Min. Typ. Max. Unit
0
-40
5
70
85
95
°c
°c
%
Hr
Pd
Relative Humidity
Derated From 100% at +50°c Linearly to 50% at 70 °c