General Purpose
Rated
800W
SNP-F80 Series
Installation Instruction
Installation (A) : AC input at lower side
Vertical assembly with bracket
Installation (B) : AC input at upper side
Vertical assembly with bracket
Installation (C) :
Horizontal assembly without bracket
333.0
333.0
317.6
317.6
35.0 55.0
35.0 55.0
10.0
10.0
42.0
42.0
System
chassis
157.0
157.0
Screws to system x4
(Prefer #8-32 or M4 screws)
Screws to system x4
(Prefer #8-32 or M4 screws)
M4 Screw
M4 Screw
M4ꢀ Screwꢀ toꢀ fixꢀ bracket
M4ꢀ Screwꢀ toꢀ fixꢀ bracket
Bracket
x4
Bracket
x4
Bracket
Bracket
System chassis
System chassis
Installation (A) : AC input at lower side
Din rail hook assembly
Installation (B) : AC input at upper side
Din rail hook assembly
7.5
7.5
#6-32 Screw
x6
4.0
4.0
120.0
40.0
120.0
40.0
Output Specifications:
MODEL
OUTPUT
LOAD
VOLTAGE
RIPPLE
NOISE
LINE
REG.
LOAD
REG.
EFFICIENCY
TYPICAL
NO.
RAIL
ACCURACY
MIN. RATED MAX. PEAK
SNP-F807
SNP-F809
SNP-F80J
SNP-F80T
+12V
+24V
+36V
+48V
0.2A 66.7A
0.2A 33.5A
0.2A 22.2A
0.2A 16.7A
83.5A
42A
+11.9V~+12.1V
+23.9V~+24.1V
+35.6V~+36.4V
+47.8V~+48.2V
120mVpp
240mVpp
360mVpp
480mVpp
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
86%
88%
90%
90%
27.8A
20.8A
Note:
1. At peak load, the output can last for 8 seconds without shout down.
2. At factory, in 60% rated load condition, the output is checked to be within voltage accuracy.
3. Line regulation is defined by changing ±10% of input voltage from nominal line at rated load.
4. Load regulation is defined by changing ±40% of measured output load from 60% rated load at another output set to 60% rated load.
5. Ripple & noise is measured by using 15MHz bandwidth limited oscilloscope and terminated each output with a 0.47uF capacitor at rated load and
nominal line.
6. Hold up time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of main output at
rated load and nominal line.
7. Efficiency is measured at rated load and nominal line.
8. EMI filter (Delta 15GEE G3E-R) has to be used for the requirement of EMI.
9. Installations (A), (B) and (C) can achieve 100% rated load.
-Kevin-
** This data sheet is only for models selection. For business, engineering specification by model must be used.
4-2
AUG. 2014