描述
Remote Controlled Circuit Breaker (RCCB)

SM601BA25A1 数据手册

 浏览型号SM601BA25A1的Datasheet PDF文件第2页浏览型号SM601BA25A1的Datasheet PDF文件第3页浏览型号SM601BA25A1的Datasheet PDF文件第4页浏览型号SM601BA25A1的Datasheet PDF文件第5页浏览型号SM601BA25A1的Datasheet PDF文件第6页浏览型号SM601BA25A1的Datasheet PDF文件第7页 
Remote Controlled Circuit Breaker (RCCB)  
Three Phase  
115/200 VAC 400 Hz  
• Three Phase Only  
Single Pole  
• 28 VDC  
115/200 VAC 400 Hz  
Qualified  
PERFORMANCE DATA  
Qualified to demanding perfor-  
Rupture Levels  
3600 A (115 VAC or 28VDC for 1Pole and 115VAC for 3 Pole)  
50,000 Cycles  
mance parameters of MIL- PRF  
- 83383 standard.  
Endurance  
(Resistive & Inductive(Motor)  
Endurance (Motor)  
Use as a Relay, Circuit Breaker, Or  
Both  
5-50A: 50,000 cycles; 60-100A: 25,000 cycles  
Endurance (Lamp)  
Dielectric Strength  
Insulation Resistance  
ThermalTemperature Range  
5-25A: 50,000 cycles; 35-50A: 25,000 cycles; 60-100A: no rating  
1500V, 60Hz, MIL-STD-202, method 301, 0.5 MA max  
100 mega ohm min, MIL-STD-202, method 302  
RCCBs combine the best attri-  
butes of a circuit breaker and a  
relay. Automatically protects the  
wires and the load device dur-  
ing circuit/load breakdown, but  
allows the flight deck control of  
the load during normal opera-  
tion.  
-54°C to 71°C (-65°F to 160°F). MIL-STD-202, Method 107  
Vibration  
10G's to 2000 Hz. Exceeds MIL-STD-202, Method 204, Condition  
C, 10 microseconds max. chatter  
25G's. MIL-STD-202, Method 213, 10 microseconds max. chatter  
50,000 ft.  
Shock  
Altitude  
Weight and Cost Savings  
In distributed-load applications,  
RCCBs are a more efficient  
power distribution solution pro-  
moting cost and weight savings  
through the elimination of long  
runs of heavy cables associ-  
ated with the conventional relay  
- flight deck circuit protector  
method. Control of the RCCB  
requires only one #22 AWG  
control wire from the ICU on the  
flight deck to the RCCB.  
EMI Requirements  
MIL-STD-461, Requirements CS114 and RE102 over the frequency  
range of 14 KHz to 400 MHz and RE102 limits for Aircraft and  
Space Systems.  
EMI/RFI Susceptibility  
and Generation  
MIL-STD-461, Class 1D  
Moisture Resistance  
Salt Spray Resistance  
Sand and Dust Resistance  
Fungus Resistance  
Explosion Proof  
MIL-STD-202, method 106  
MIL-STD-202, method 101, Condition B  
MIL-STD-202, method 110, Condition A  
MIL-HDBK-454, Guideline 4  
MIL-STD-202, method 109  
Weight (Single Pole)  
5-25A: 318 grams (0.703 lbs.); 35-50A: 325 grams (0.719 lbs.); 60-  
100A: 332 grams (0.734 lbs.)  
Cockpit Space Savings  
An RCCB system removes the  
presence of large circuit break-  
ers from the cockpit while per-  
mitting remote On/Off operation  
from the flight deck. Combine  
Eaton RCCB with Indicator  
Control Unit (ICU) model #1500-  
052-05.  
Weight (w/ Auxiliary Contacts)  
5-25A: 332 grams (0.734 lbs.); 35-50A: 339 grams (0.750 lbs.); 60-  
100A: 346 grams (0.766 lbs.)  
Weight (Three Phase)  
2.0 lbs. max.  
OVERLOAD CALIBRATION DATA  
@ 25°C  
@ +71°C  
@ -54°C  
MAX  
TestTime  
Parameters  
% for 1 Hour  
Specification  
Table  
Must Hold  
Must Trip  
MIN MAX  
MAX  
MIN  
115%  
MIN  
115%  
115%  
138%  
138%  
% Within 1 Hour  
150%  
10  
EATON CORPORATION Aerospace TF300-0 January 2005  

与SM601BA25A1相关器件

型号 品牌 获取价格 描述 数据表
SM601BA35A1 EATON

获取价格

Remote Controlled Circuit Breaker (RCCB)
SM601BA40A1 EATON

获取价格

Remote Controlled Circuit Breaker (RCCB)
SM601BA50A1 EATON

获取价格

Remote Controlled Circuit Breaker (RCCB)
SM601BA60A1 EATON

获取价格

Remote Controlled Circuit Breaker (RCCB)
SM601HRR MICROSEMI

获取价格

SWITCHING REGULATOR POWER OUTPUT STAGES
SM601R MICROSEMI

获取价格

SWITCHING REGULATOR POWER OUTPUT STAGES
SM602 MICROSEMI

获取价格

SWITCHING REGULATOR POWER OUTPUT STAGES
SM602F1K LITTELFUSE

获取价格

Littelfuse LL-34 “MiniMELF”型玻璃封装表面贴装式热敏电阻采用密封
SM602HRR MICROSEMI

获取价格

SWITCHING REGULATOR POWER OUTPUT STAGES
SM602R MICROSEMI

获取价格

SWITCHING REGULATOR POWER OUTPUT STAGES