CCD area image sensor S7010/S7011/S7015 series
ꢀ Timing chart
Line binning
INTEGRATION PERIOD
(Shutter must be open)
VERTICAL BINNING PERIOD
(Shutter must be closed)
READOUT PERIOD (Shutter must be closed)
64← 60 + 4 (ISOLATION): S701 -0906/-1006
3.. 62 63
*
3..126 127
3..254 255
128← 124 + 4 (ISOLATION): S701 -0907/-1007
256← 252 + 4 (ISOLATION): S701 -0908/-1008
Tpwv
*
*
1
2
P1V
Tovr
P2V, TG
P1H
4..530 531
Tpwh, Tpws
532 : S701 -0906/-0907/-0908
*
4..1042 1043
1044: S701 -1006/-1007/-1008
*
1
2
3
P2H, SG
Tpwr
D1
RG
OS
D2
S1..S512
D19
D20: S701 -0906/-0907/-0908
*
D3..D10, S1..S1024, D11..D18
: S701 -1006/-1007/-1008
*
KMPDC0122EA
Parameter
Pulse width
Symbol
Tpwv
Remark
Min.
6 *13
Typ.
Max.
Unit
µ
-
-
-
-
-
-
-
-
-
-
-
-
-
s
12
*
P1V, P2V, TG
P1H, P2H
Rise and fall time
Pulse width
Tprv, Tpfv
Tpwh
200
500
10
-
ns
ns
ns
%
-
12
*
Rise and fall time
Duty ratio
Tprh, Tpfh
-
-
50
-
Pulse width
Tpws
500
10
-
ns
ns
%
SG
Rise and fall time
Duty ratio
Tprs, Tpfs
-
-
-
50
-
Pulse width
Tpwr
100
5
ns
ns
µs
RG
-
-
Rise and fall time
Overlap time
Tprr, Tpfr
Tovr
-
TG P1H
3
-
*12: Symmetrical pulses should be overlapped at 50 % of maximum amplitude.
*13: In case of S701 -0908/-1007.
*
Area scanning 1: low dark current mode
INTEGRATION PERIOD
(Shutter must be open)
READOUT PERIOD (Shutter must be closed)
64← 60 + 4 (ISOLATION): S701 -0906/-1006
4.. 63
4..127
4..255
*
128←124 + 4 (ISOLATION): S701 -0907/-1007
*
Tpwv
256←252 + 4 (ISOLATION): S701 -0908/-1008
*
1
2
3
P1V
P2V, TG
P1H
P2H, SG
RG
OS
Tovr
P2V, TG
ENLARGED VIEW
Tpwh, Tpws
P1H
P2H, SG
RG
Tpwr
D1
OS
S1..S512
D5..D10, S1..S1024, D11..D17
D2
D3
D4
D18
D19
D20: S701 -0906/-0907/-0908
*
: S701 -1006/-1007/-1008
*
KMPDC0123EA
4