5秒后页面跳转
S506-V-250-R PDF预览

S506-V-250-R

更新时间: 2024-01-29 01:29:59
品牌 Logo 应用领域
库柏 - COOPER 电路保护
页数 文件大小 规格书
1页 60K
描述
Electric Fuse, Time Delay Blow, 0.25A, 250VAC, 35A (IR), Through Hole, ROHS COMPLIANT

S506-V-250-R 技术参数

是否无铅: 不含铅是否Rohs认证: 符合
生命周期:Transferred包装说明:ROHS COMPLIANT
Reach Compliance Code:compliantECCN代码:EAR99
HTS代码:8536.10.00.40风险等级:5.72
熔断特性:TIME DELAY电路保护类型:ELECTRIC FUSE
焦耳积分标称:安装特点:THROUGH HOLE
额定分断能力:35 A额定电流:0.25 A
额定电压(交流):250 V参考标准:CE; IEC; IMQ; SEMKO; UL; VDE
表面贴装:NO端子面层:Nickel (Ni)
端子形状:PIN WIREBase Number Matches:1

S506-V-250-R 数据手册

  
Electronic — PCB & Small Dimension Fuses  
5 x 20mm European (IEC) ferrule fuses  
S500-V (GDB-V) (axial leads)  
S500 (GDB)  
S501-V (GDA-V) (axial leads)  
S506-V (GDC-V) (axial leads)  
S501 (GDA)  
S506 (GDC)  
Specifications  
Description: Fast-  
acting, low-breaking  
capacity fuse.  
Specifications  
Specifications  
Description: Time-  
delay, low-breaking  
capacity fuse.  
Description: Fast-  
acting, high-break-  
ing capacity fuse.  
Construction:  
Glass tube, nickel-  
plated brass end-  
caps.  
Construction:  
Ceramic tube, nick-  
el-plated brass end-  
caps.  
Construction:  
Glass tube, nickel-  
plated brass end-  
caps.  
Ratings:  
Ratings:  
Ratings:  
Volts — 250Vac (or less)  
Amps — 32mA-16A  
IR — 35A @ 250Vac  
Volts — 250Vac (or less)  
Amps — 50mA-6.3A  
IR — 1500A @ 250Vac  
Volts — 250Vac (or less)  
Amps — 32mA-6.3A  
IR — 35A @ 250Vac  
Agency Information: CE, Designed to  
IEC 60127-Sheet II British Standard  
Approval SEMKO Approval VDE  
Approval, IMQ UL Recognized, Guide  
JDYX2, File E19180, 32mA-6.3A.  
Agency Information: CE, UL  
Recognized, Guide JDYX2, File  
E19180, 50mA and 315mA-6.3A  
SEMKO Approval 50mA, 200mA and  
315mA-6.3A, IEC 60127-Sheet I, VDE  
Approval 1.25A-6.3A.  
Agency Information: CE, Designed  
to IEC 60127-Sheet III British  
Standard Approval SEMKO Approval  
VDE Approval, IMQ UL Recognized,  
Guide JDYX2, File E19180,  
32mA-6.3A.  
Features and Benefits  
Features and Benefits  
Features and Benefits  
• Time-delay compatibility for inductive  
circuits.  
• Fast-acting for maximum protection,  
conforms to IEC standards.  
• Fast-acting for maximum protection.  
• High break capacity for use in higher  
fault energy electronic circuitry.  
• Conforming to IEC standards.  
Typical Applications  
• Electronic Circuits  
• Conforming to IEC standards.  
Typical Applications  
• Electronic Circuits  
Catalog Numbers (Amps)  
Catalog  
Max Voltage  
Drop (mV)  
Typical Applications  
• Electronic Circuits  
2
Numbers  
I t  
Catalog Numbers (Amps)  
S500-32  
S500-40  
S500-50  
S500-63  
S500-80  
S500-100  
S500-125  
S500-160  
S500-200  
S500-250  
S500-315  
S500-400  
S500-500  
S500-630  
S500-800  
S500-1  
S500-1.25  
S500-1.6  
S500-2  
S500-2.5  
S500-3.15  
S500-4  
S500-5  
S500-6.3  
S500-8*  
0.000047  
0.00011  
0.00020  
0.00057  
0.0012  
0.003  
0.005  
0.008  
0.016  
0.028  
0.058  
0.018  
0.018  
0.035  
0.067  
0.60  
10000  
8000  
3200  
2500  
2200  
2100  
2000  
1950  
1600  
1400  
1150  
950  
220  
220  
180  
200  
200  
190  
160  
145  
130  
120  
115  
110  
Catalog  
Max Voltage  
Drop (mV)  
Catalog Numbers (Amps)  
2
Numbers  
I t  
Catalog  
Numbers  
Max Voltage  
Drop (mV)  
2
I t  
S506-32  
S506-40  
S506-50  
S506-63  
S506-80  
S506-100  
S506-125  
S506-160  
S506-200  
S506-250  
S506-315  
S506-400  
S506-500  
S506-630  
S506-800  
S506-1  
0.0014  
0.0034  
0.006  
0.012  
0.015  
0.022  
0.034  
0.052  
0.078  
0.17  
0.41  
0.61  
0.75  
1.3  
1050  
920  
800  
760  
580  
490  
390  
320  
340  
270  
250  
210  
168  
158  
132  
85  
S501-50  
S501-63  
S501-80  
S501-100  
S501-125  
S501-160  
S501-200  
S501-250  
S501-315  
S501-400  
S501-500  
S501-630  
S501-800  
S501-1  
0.0017  
0.0005  
0.0011  
0.0018  
0.0037  
0.008  
0.020  
0.027  
0.010  
0.018  
0.038  
0.064  
0.097  
0.480  
0.9  
9000  
3300  
2600  
2300  
1900  
1600  
1350  
1300  
1400  
1200  
1050  
1200  
490  
230  
200  
180  
205  
190  
160  
160  
155  
0.84  
1.6  
4.2  
6.1  
3.1  
3.6  
S501-1.25  
S501-1.6  
S501-2  
S506-1.25  
S506-1.6  
S506-2  
S506-2.5  
S506-3.15  
S506-4  
7
10  
17  
34  
56  
80  
80  
80  
80  
75  
75  
1.9  
2.0  
13  
22  
42  
69  
S501-2.5  
S501-3.15  
S501-4  
3.9  
8.1  
14  
91  
S501-5  
S501-6.3  
25  
48  
S506-5  
S506-6.3  
-
133  
270  
75  
65  
S500-10*  
S500-12*  
S500-16*  
150  
Options  
Options  
*IEC Standard 127 Sheet II does not include ratings above 6.3A.  
Axial leads, put “V” in P/N,  
RoHS compliant, put “R” suffix in P/N.  
Example: S501-V-1.25-R.  
Axial leads, put “V” in P/N,  
RoHS compliant, put “R” suffix in P/N.  
Example: S506-V-1.25-R.  
Options  
Axial leads, put “V” in P/N,  
RoHS compliant, put “R” suffix in P/N.  
Example: S500-V-1.25-R.  
Data Sheet: 2014  
Data Sheet: 2016  
Data Sheet: 2015  
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp  
55  

与S506-V-250-R相关器件

型号 品牌 描述 获取价格 数据表
S506-V-2A COOPER Fuse,

获取价格

S506-V-3.15MA COOPER Fuse,

获取价格

S506-V-315MA COOPER Fuse,

获取价格

S506-V-315-R COOPER Electric Fuse, Time Delay Blow, 0.315A, 250VAC, 35A (IR), Through Hole, ROHS COMPLIANT

获取价格

S506-V-32MA COOPER Fuse,

获取价格

S506-V-40 COOPER Electric Fuse, Time Delay Blow, 0.04A, 250VAC, 35A (IR), Through Hole

获取价格