ECONOLINE - DC/DC-Converter
REC3-S/DRW(Z) Series, 3W, DIP24, Regul., Wide Input 2:1 & 4:1 (Single & Dual Output)
Selection Guide
Part
Number
DIP24
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
(%)
74
79
80
80
74
79
79
74
79
80
80
74
78
78
REC3-XX05SRW*
REC3-XX09SRW*
REC3-XX12SRW *
REC3-XX15SRW*
REC3-XX05DRW*
REC3-XX12DRW*
REC3-XX15DRW*
REC3-XX05SRWZ*
REC3-XX09SRWZ*
REC3-XX12SRWZ*
REC3-XX15SRWZ*
REC3-XX05DRWZ*
REC3-XX12DRWZ*
REC3-XX15DRWZ*
9 - 18, 18 - 36, 36 - 72
9 - 18, 18 - 36, 36 - 72
9 - 18, 18 - 36, 36 - 72
9 - 18, 18 - 36, 36 - 72
9 - 18, 18 - 36, 36 - 72
9 - 18, 18 - 36, 36 - 72
9 - 18, 18 - 36, 36 - 72
9 - 36, 18 - 72
5
9
600
330
250
200
300
125
100
600
330
250
200
300
125
100
Features
12
15
5
● 3W DIP Package
● Short Circuit Protection
● Regulated Output
● 100% Burned In
● Cost Effective
● UL94V-0 Package Material
● Efficiency to 80%
● 1kVDC Isolation
12
15
5
9 - 36, 18 - 72
9
9 - 36, 18 - 72
12
15
5
9 - 36, 18 - 72
9 - 36, 18 - 72
9 - 36, 18 - 72
12
15
9 - 36, 18 - 72
XX = 9-18Vin = 12
XX = 18-36Vin = 24
XX = 36-72Vin = 48
XX = 9-36Vin = 24
XX = 18-72Vin = 48
*add „/A“, „/ B“ or „/ C“ for Pinning, see next page.
Specifications (Core Operating Area) and Operating Temperature / Derating-Graph
Voltage Setting Accuracy
Temperature Coefficient
Ripple and Noise (20MHz BW)
Line Regulation (HL-LL)
Load Regulation (for output load current change from 10% to 100%)
Short Circuit Protection
Operating Temperature
Storage Temperature
Cooling
2% max.
3rd angle
projection
0.03%/ꢀC
100mVp-p max.
0.2% max.
0.2% max.
6.0
4.5
3.0
1,5
Continuous
-25ꢀC to +70ꢀC (see Graph)
-55ꢀC to +100ꢀC
Free-Air Convection
Pi Network
Input Filter
Safe Operating Area
Efficiency
70% min.
Isolation Voltage
1.000VDC min.
109 ohms min.
25 kHz min.
0
Isolation Resistance
-25
0
50
100
150
Switching Frequency at Full Load
Isolation Capacitance
Weight
70
Operating Temperature ˚C
125
80pF max.
14.6g
Case Material
Non-Conductive Plastic
www.recom-international.com
August 2002
EC 75