MODEL: R7C
I ENGINEERING UNIT CONVERSION
Engineering unit value °C or K is multiplied by 10 and expressed in 16 bits. °F data is represented in engineering unit
value, without multiplication. Engineering unit value A is multiplied by 100 or 1000, expressed in 16 bits. Negative value
is represented in 2ʼs complements.
• Input TYPE K Thermocouple
Converted Data, Decimal
Converted Data, Hex
Input Value
≤ -272°C
-150°C
-2720
-1500
13700
14720
F560
FA24
3584
3980
1370°C
≥ 1472°C
14720 (3980)
13700 (3584)
-272 -150
1370
1472
(°C)
-1500 (FA24)
-2720 (F560)
■ COUNT VALUE
The count value is 32-bit data. It is divided in 2 words of 16 bits represented with 2 addresses.The lower address is
allocated in the lower word (LSB) and the upper address in the upper word (MSB). The count value is 0 - 4 294 967 295.
The maximum count value available is 1 000 - 4 294 967 295. In case of overflow, the vaule is reset to 0 or 1
(configurable) from which the count will restart. The preset of the count value is also available. Use the R7CON or
commands for the configuration.
R7C SPECIFICATIONS
ES-7801 Rev.26 Page 7/46
http://www.m-system.co.jp/