Q24T30020 DC-DC Converter Data Sheet
18-36 VDC Input; 2.0 VDC @ 30A Output
Electrical Specifications
Conditions: TA=25ºC, Airflow=300 LFM (1.5 m/s), Vin=24 Vdc, unless otherwise specified.
PARAMETER
NOTES
MIN
TYP
MAX UNITS
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Operating Ambient Temperature
Storage Temperature
Continuous
0
-40
-55
40
85
125
Vdc
°C
°C
INPUT CHARACTERISTICS
Operating Input Voltage Range
Input Under Voltage Lockout
Turn-on Threshold
18
24
36
Vdc
Non-latching
16
15
17
16
17.5
16.5
Vdc
Vdc
Turn-off Threshold
OUTPUT CHARACTERISTICS
External Load Capacitance
Output Current Range
Current Limit Inception
Peak Short-Circuit Current
RMS Short-Circuit Current
Plus full load (resistive)
30,000
30
40
55
8
µF
Adc
Adc
A
0
33
Non-latching
Non-latching. Short=10mΩ.
Non-latching
36
45
Arms
ISOLATION CHARACTERISTICS
I/O Isolation
Isolation Capacitance
2000
10
Vdc
ρF
Mꢀ
230
435
Isolation Resistance
FEATURE CHARACTERISTICS
Switching Frequency
kHz
%
Output Voltage Trim Range1
Use trim equations on Page 6
Percent of VOUT(NOM)
-20
+10
+10
127
Remote Sense Compensation1
%
Output Over-Voltage Protection
Over-Temperature Shutdown (PCB)
Auto-Restart Period
Non-latching
Non-latching
Applies to all protection features
117
122
118
100
2.5
%
°C
ms
ms
Turn-On Time
ON/OFF Control (Positive Logic)
Converter Off
-20
2.4
0.8
20
Vdc
Vdc
Converter On
ON/OFF Control (Negative Logic)
Converter Off
2.4
-20
20
0.8
Vdc
Vdc
Converter On
Additional Notes:
1. Vout can be increased up to 10% via the sense leads or up to 10% via the trim function, however total output voltage trim from all sources
should not exceed 10% of VOUT(NOM), in order to insure specified operation of over-voltage protection circuitry. See further discussion at end of
Output Voltage Adjust /TRIM section.
JUN 01, 2003 revised to NOV 22, 2006
Page 2 of 14