PWA_LT-1W5 & PWB_LT-1W5 Series
1.5W, WIDE INPUT ISOLATED & REGULATED
SINGLE/DUAL OUTPUT DC/DC CONVERTER
MINIATURE SMD PACKAGE
multi-country patent protection RoHS
FEATURES
PRODUCT PROGRAM
Input
Output
Wide (4:1) Input Range
Short Circuit Protection(automatic recovery)
1500VDC Isolation
Operating Temperature: -40°C to +85°C
No Heat Sink Required
No external component required
MTBF>1,000,000 hours
Part
Number
Efficiency
(%, Typ)
Voltage (VDC)
Current (mA)
Voltage
(VDC)
Nominal
Range
9.0-36
Max**
Max
±150
±63
Min
±15
±6
PWA2405LT-1W5
PWA2412LT-1W5*
PWA2415LT-1W5*
PWB2403LT-1W5*
PWB2405LT-1W5*
±5
±12
±15
3.3
5
74
78
80
72
76
±50
±5
455
300
45
30
24
40
RoHS Compliance
PWB2409LT-1W5*
PWB2412LT-1W5*
PWB2415LT-1W5*
PWA4805LT-1W5*
PWA4812LT-1W5*
PWA4815LT-1W5*
9
167
125
100
±150
±63
±50
17
12
78
79
80
74
76
78
12
15
10
±5
±15
±6
APPLICATIONS
±12
±15
The PWA_LT-1W5 & PWB_LT-1W5 Series are
specially designed for applications where a wide
range input voltage power supplies are isolated
from the input power supply in a distributed
power supply system on a circuit board.
These products apply to:
±5
PWB4803LT-1W5*
PWB4805LT-1W5*
PWB4809LT-1W5*
PWB4812LT-1W5*
PWB4815LT-1W5*
*Designing.
3.3
5
455
300
167
125
100
45
30
17
12
10
72
76
78
79
80
48
18-72
80
9
12
15
1) Where the voltage of the input power supply is
wide range(voltage range≤4:1);
**Input voltage can’t exceed this value, or will cause the permanent damage.
Note: The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
2) Where isolation is necessary between input
and output (Isolation Voltage ≤1500 VDC);
3) Where the regulation of the output voltage
and the output ripple noise are demanded.
ISOLATION SPECIFICATIONS
Item
Test Conditions
Min
Typ
85
Max
Units
VDC
MΩ
Isolation voltage
Isolation resistance
Isolation Capacitance
Tested for 1 minute and 1mA max
Test at 500VDC
1500
1000
Input/Output
pF
MODEL SELECTION
PWA2405LT-1W5
OUTPUT SPECIFICATIONS
Rated Power
Package Style
Output Voltage
Item
Test conditions
Min
Typ
Max
1.5
±3
Units
W
Output Power
See above products program
0.15
Input Voltage
Positive voltage accuracy Refer to recommended circuit
Negative voltage accuracy Refer to recommended circuit
±1
±3
Product Series
±5
%
Load Regulation
From 10% to 100% load
±0.5 ±1.5*
±0.2 ±0.75
Line Regulation
Input voltage from low to high
Refer to recommended circuit
20MHz Bandwidth
Temperature Drift (Vout)
Output ripple& Noise**
Switching Frequency
0.03 %/°C
35
75
mVp-p
KHz
MORNSUN Science & Technology co.,Ltd.
100% load, nominal input voltage
300
Address: 2th floor 6th building, Huangzhou
Industrial District, Guangzhou, China
Tel: 86-20-38601850
*Dual output models unbalanced load: ±5%.
**Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power
Converter section, application notes.
Fax: 86-20-38601272
Note:
Http://www.mornsun-power.com
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load unless
Otherwise specified.
2. See below recommended circuits for more details.
MORNSUN reserves the copyright
Specifications subject to change without notice.
PWA_LT_1W5 & PWB_LT_1W5
A/2-2008
Page 1 of 2