PS1201
Absolute Maximum Ratings (@ 25˚C)
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter
Blocking Voltage
Min
-
Max
400
5
Units
VP
Reverse Input Voltage
Input Control Current
Peak (10ms)
-
V
-
-
100
1
mA
A
Input Power Dissipation 1
Total Package Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature
-
150
1600
-
mW
mW
Vrms
ºC
-
3750
-40
-40
+85
+125
Storage Temperature
Derate Linearly 1.33 mW / ºC
Derate Linearly 16.6 mW / ºC
ºC
1
2
Electrical Characteristics
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics @ 25°C
AC Operating Voltage
Load Current (Continuous)
Maximum Surge Current
Off-State Leakage Current
On-State Voltage Drop
Critical Rate of Rise
IF=5mA
VOP
IL
20
-
120
1
Vrms
Arms
A
VL=120-240VAC
t<16ms
0.005
-
IPEAK
ILEAK
-
-
-
20
1
VL=400VDC
IL=1Arms
-
-
-
-
-
mA
Vrms
V/µs
1.2
-
dV/dt
1000
1200
Switching Speeds
Turn-On
TON
-
-
-
0.5
0.5
5
IF=5mA
Cycles
Turn-Off
TOFF
-
Zero-Cross Turn-On Voltage
1st half-cycle
-
-
2
-
V
V
-
Subsequent half-cycle
1
Operating Frequency 1
-
-
-
-
20
0.25
-
-
500
-
Hz
-
Load Power Factor for Guaranteed Turn-On 2
Capacitance Input-To-Output
Input Characteristics @ 25°C
Input Control Current
PF
CI/O
-
3
-
pF
For Normal Environment
For High Noise Environment
Input Voltage Drop
-
-
-
-
5
10
1.4
-
IF
mA
-
-
1.2
-
IF=5mA
-
VF
-
0.9
0.8
-
V
V
Input Dropout Voltage
Reverse Input Current
Zero Cross 1st half-cycle @ < 100Hz.
VR=5V
IR
-
10
µA
1
2
Snubber circuits may be required at low power factors.
R11
2
www.clare.com