Powerex, Inc., 200 E. Hillis Street,Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM450CLA060
Intellimod™ L-Series
Three Phase IGBT Inverter
450 Amperes/600 Volts
Absolute Maximum Ratings, T = 25°C unless otherwise specified
j
Characteristics
Symbol
PM450CLA060
-20 to 150
-40 to 125
31
Units
°C
Power Device Junction Temperature
Storage Temperature
T
j
T
stg
°C
Mounting Torque, M5 Mounting Screws
Mounting Torque, M6 Main Terminal Screws
Module Weight (Typical)
—
in-lb
in-lb
Grams
Volts
Volts
Volts
—
—
40
1250
Supply Voltage, Surge (Applied between P - N)
Self-protection Supply Voltage Limit (Short Circuit protection Capability)*
Isolation Voltage, AC 1 minute, 60Hz Sinusoidal
V
500
CC(surge)
V
400
CC(prot.)
V
ISO
2500
*V = 13.5 ~ 16.5V, Inverter Part, Tj = 125°C
D
IGBT Inverter Sector
Collector-Emitter Voltage (V = 15V, V
= 15V)
V
600
450
Volts
D
CIN
CES
Collector Current (T = 25°C)
±I
Amperes
Amperes
Watts
C
C
Peak Collector Current (T = 25°C)
±I
CP
900
C
Collector Dissipation (T = 25°C)
C
P
1041
C
Control Sector
Supply Voltage (Applied between V
-V
, V
, V -V
-V
,
V
20
20
20
20
Volts
Volts
Volts
mA
UP1 UPC VP1 VPC
D
V
-V
, V
-V
, V
-V
)
WP1 WPC UN1 UNC WN1 WNC N1 NC
Input Voltage (Applied between U -V
, V -V
UPC
, W -V
,
V
CIN
P
P
VPC
P
WPC
U -V
, V -V
, W -V )
WNC
N
UNC
N
VNC
N
Fault Output Supply Voltage (Applied between U
-V
, V
-V
,
V
FO
PFO UPC PFO VPC
W
-V
, U
-V
, V
-V
, W
-V )
NFO WNC
PFO WPC NFO UNC NFO VNC
Fault Output Sink Current at U , V
, W
, U
, V
, W
Terminals
NFO
I
PFO PFO PFO NFO NFO
FO
2