MITSUBISHI <INTELLIGENT POWER MODULES>
PM100RSE120
FLAT-BASE TYPE
INSULATED PACKAGE
BRAKE PART
Limits
Unit
Test Condition
Symbol
Parameter
Min.
—
Typ.
2.65
2.60
2.5
Max.
3.30
3.25
3.5
1
Collector-Emitter
VD = 15V, IC = 50A
VCIN = 0V, Pulsed
IF = 50A
Tj = 25°C
(Fig. 1) Tj = 125°C
(Fig. 2)
VCE(sat)
VFM
V
V
—
Saturation Voltage
FWDi Forward Voltage
Collector-Emitter
Cutoff Current
—
Tj = 25°C
—
—
V
CE = VCES, VCIN = 15V
(Fig. 4)
ICES
mA
Tj = 125°C
—
—
10
CONTROL PART
Limits
Typ.
60
Symbol
Parameter
Circuit Current
Test Condition
VD = 15V, VCIN = 15V
Unit
mA
V
Min.
—
Max.
82
VN1-VNC
ID
VXP1-VXPC
—
15
20
Input ON Threshold Voltage
Input OFF Threshold Voltage
Vth(on)
Vth(off)
Applied between : UP-VUPC, VP-VVPC, WP-VWPC
1.2
1.7
228
145
1.5
2.0
345
—
1.8
2.3
—
UN • VN • WN • Br-VNC
Tj = 25°C
Inverter part
Tj = 125°C
(Fig. 5,6)
—
VD = 15V
Over Current Trip Level
A
OC
Break part
75
—
—
–20 ≤ Tj ≤ 125°C, VD = 15V
(Fig. 5,6)
Inverter part
Brake part
(Fig. 5,6)
—
—
340
144
10
—
—
Short Circuit Trip Level
SC
–20≤ Tj ≤ 125°C, VD = 15V (Fig. 5,6)
A
µs
°C
Over Current Delay Time
Over Temperature Protection
toff(OC)
OT
VD = 15V
—
—
Trip level
Base-plate
111
—
118
100
12.0
12.5
—
125
—
Reset level
Trip level
OTr
Temperature detection, VD = 15V
Supply Circuit Under-Voltage
Protection
UV
12.5
—
11.5
—
V
–20 ≤ Tj ≤ 125°C
VD = 15V, VFO = 15V
VD = 15V
Reset level
UVr
IFO(H)
IFO(L)
—
0.01
15
Fault Output Current
mA
ms
(Note-3)
(Note-3)
—
10
Minimum Fault Output Pulse
Width
tFO
1.0
1.8
—
(Note-3) Fault output is given only when the internal OC, SC, OT & UV protection.
Fault output of OT protection operate by lower arm.
Fault output of OC, SC protection given pulse.
Fault output of OT, UV protection given pulse while over level.
MECHANICAL RATINGS AND CHARACTERISTICS
Limits
Typ.
3.0
Unit
Test Condition
Parameter
Mounting torque
Symbol
Min.
2.5
2.5
—
Max.
3.5
3.5
—
—
—
—
Main terminal
Mounting part
screw : M5
screw : M5
N • m
3.0
Mounting torque
Weight
N • m
g
920
—
RECOMMENDED CONDITIONS FOR USE
Symbol Parameter
Supply Voltage
Test Condition
Recommended value
Unit
V
VCC
Applied across P-N terminals
≤ 800
Applied between : VUP1-VUPC, VVP1-VVPC
VWP1-VWPC, VN1-VNC
VD
Control Supply Voltage
15 ± 1.5
V
V
(Note-4)
Input ON Voltage
Input OFF Voltage
VCIN(on)
VCIN(off)
Applied between : UP-VUPC, VP-VVPC, WP-VWPC
UN • VN • WN • Br-VNC
≤ 0.8
≥ 4.0
Using Application Circuit input signal of IPM, 3φ
PWM Input Frequency
fPWM
tdead
≤ 20
kHz
µs
sinusoidal PWM VVVF inverter
(Fig. 8)
(Fig. 7)
Arm Shoot-through
Blocking Time
For IPM’s each input signals
≥ 3.0
(Note-4) Allowable Ripple rating of Control Voltage : dv/dt ≤ ±5V/µs, 2Vp-p
Jul. 2005