Additional Resources: Product Page
|
3D Model
|
PCB Footprint
CUI Inc │SERIES: PDQ15-D │ DESCRIPTION: DC-DC CONVERTER
date 07/12/2016 │ page 3 of 9
PROTECTIONS
parameter
conditions/description
min
typ
max
units
zener or TVS clamp
3.3 Vdc output models
5 Vdc output models (single and dual)
12 Vdc output models (single and dual)
15 Vdc output models (single and dual)
3.9
6.2
15
Vdc
Vdc
Vdc
Vdc
over voltage protection
18
over current protection
short circuit protection
hiccup mode
110
140
160
%
continuous, automatic recovery
SAFETY AND COMPLIANCE
parameter
conditions/description
min
typ
max
units
Vdc
MΩ
isolation voltage
isolation resistance
isolation capacitance
input to output for 1 minute
input to output
1,500
1,000
input to output
1,000
pF
EN 55022 Class A (external circuit required, see
Figure 3)
conducted emissions
as per MIL-HDBK-217F, GB, full load, 25°C
3.3, 5 Vdc output models
all other models
MTBF
950,000
1,300,000
hours
hours
RoHS
2011/65/EU
ENVIRONMENTAL
parameter
conditions/description
min
-40
-55
typ
typ
max
105
125
95
units
°C
operating temperature
storage temperature
operating humidity
see derating curves
°C
non-condensing
%
SOLDERABILITY
parameter
conditions/description
min
max
units
wave soldering
see wave soldering profile
260
°C
Notes:
1. Soldering materials: Sn/Cu/Ni
2. Ramp up rate during preheat: 1.4°C/s (from 50°C to 100°C)
3. Soaking temperature: 0.5°C/s (from 100°C to 130°C), 60±20 seconds
4. Peak temperature: 260°C, above 250°C for 3~6 seconds
5. Ramp down rate during cooling: -10°C/s (from 260°C to 150°C)
Time (Seconds)
cui.com