PA-750
PRESSURE TRANSDUCERS WITH AMP.
■
LIST OF MODEL NUMBERS
Pressure reference
Gauge
Absolute
Fitting
kPa
Cable
0 ~ 100 (abs)
0 ~ 100
0 ~ 350
0 ~ 1000
0 ~ 3500
0 ~ − 100
− 100 ~ 100
− 100 ~ 300
Rated pressure range
PA-750-
PA-750-
PA-750-
103G-R1
PA-750-
353G-R1
PA-750-
PA-750-
102R-R1
PA-750-
302R-R1
PA-750-
102A-R1
Attached
A
102G-R1
A
352G-R1
A 102V-R1
R1
R2
PA-750-
PA-750-
PA-750-
PA-750-
PA-750-
PA-750-
PA-750-
PA-750-
Not attached
Attached
A
102G-R1-1
A
352G-R1-1
103G-R1-1
353G-R1-1
A
102V-R1-1
102R-R1-1
302R-R1-1
102A-R1-1
PA-750-
PA-750-
PA-750-
PA-750-
PA-750-
PA-750-
PA-750-
PA-750-
A
102G-R2
A
352G-R2
103G-R2
353G-R2
A
102V-R2
102R-R2
302R-R2
102A-R2
PA-750-
PA-750-
PA-750-
PA-750-
PA-750-
PA-750-
PA-750-
PA-750-
Not attached
A
102G-R2-1
A
352G-R2-1
103G-R2-1
353G-R2-1
102R-R2-1
302R-R2-1
102A-R2-1
A
102V-R2-1
※Verify the above model numbers when placing orders.
A
ꢀ
The products marked
are manufactured upon receipt of order basis.
■
STANDARD SPECIFICATIONS
● Unless otherwise specified, the specs are defined at an ambient temperature of 25 5 °C and excitation voltage of 12 V DC.
PA-750
Item
Model number
102G
352G
103G
353G
102V
102R
302R
102A
Pressure reference
Gauge
Absolute
Rated pressure range
Maximum pressure
Break-down pressure
Operating temp. range
Compensated temp. range
Operating humidity
Storage temp.
kPa
kPa
kPa
°C
100
200
300
350
700
1000
2000
3000
3500
5000
7000
− 100
200
− 100 ~ 100
200
− 100 ~ 300
600
100 (abs)
200 (abs)
300 (abs)
1050
300
300
900
− 20 ~ 80
°C
0 ~ 50
%RH
°C
35 ~ 85(
No condensation)
− 20 ~ 80(Atmospheric pressure, humidity 65 %RH maximum)
Pressure medium
Insulation resistance
Dielectric strength
Sealed liquid
Corrosive gases/liquids compatible with SUS 316L or SUS304
100 (500 V DC)
MΩ
minimum
500 V AC, 60 s
(
Leakage current 1 mA maximum
)
Silicone oil
Pressure port
R 1/86R 1/4ꢀ
Net weight
g
R2 : Approx. 50
IP65
Drip-proof structure