MAXIMUM RATINGS
Rating
Symbol
Value
400
Unit
kPa
kPa
°C
(8)
Overpressure (P1 > P2)
P
max
(8)
Burst Pressure (P1 > P2)
P
burst
1000
Storage Temperature
Operating Temperature
T
stg
–40 to +125
–40 to +125
T
A
°C
OPERATING CHARACTERISTICS (V = 10 Vdc, T = 25°C unless otherwise noted, P1 > P2)
S
A
Characteristic
Symbol
Min
0
Typ
—
Max
100
16
Unit
kPa
(1)
Pressure Range
P
OP
(2)
Supply Voltage
Supply Current
Full Scale Span
V
S
—
—
10
Vdc
I
o
6.0
—
mAdc
mV
(3)
MPX2100A, MPX2100D, MPX2101D
MPX2101A
V
FSS
38.5
37.5
40
40
41.5
42.5
(4)
Offset
MPX2100D, MPX2101D
MPX2100A
MPX2101A
V
off
–1.0
–2.0
–3.0
—
—
—
1.0
2.0
3.0
mV
Sensitivity
(5)
∆V/∆P
—
0.4
—
mV/kPa
Linearity
MPX2100D
MPX2100A
MPX2101D
MPX2101A
—
—
–0.25
–1.0
–0.5
–2.0
—
—
—
—
0.25
1.0
0.5
2.0
%V
FSS
(5)
Pressure Hysteresis (0 to 100 kPa)
—
—
—
—
±0.1
±0.5
—
—
—
%V
%V
%V
FSS
FSS
FSS
(5)
Temperature Hysteresis (–40°C to +125°C)
(5)
Temperature Effect on Full Scale Span
TCV
FSS
–1.0
–1.0
1000
1400
—
1.0
1.0
2500
3000
—
(5)
Temperature Effect on Offset
Input Impedance
TCV
off
—
mV
Z
in
—
Ω
Ω
Output Impedance
Z
out
—
(6)
Response Time (10% to 90%)
Warm–Up
t
R
1.0
20
ms
ms
—
—
—
—
(9)
Offset Stability
—
±0.5
—
%V
FSS
MECHANICAL CHARACTERISTICS
Characteristic
Symbol
Min
—
Typ
2.0
—
Max
—
Unit
Grams
kPA
Weight (Basic Element Case 344–15)
—
—
(7)
Common Mode Line Pressure
—
690
NOTES:
1. 1.0 kPa (kiloPascal) equals 0.145 psi.
2. Device is ratiometric within this specified excitation range. Operating the device above the specified excitation range may induce additional
error due to device self–heating.
3. Full Scale Span (V
) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
minimum rated pressure.
FSS
4. Offset (V ) is defined as the output voltage at the minimum rated pressure.
off
5. Accuracy (error budget) consists of the following:
•
Linearity:
Output deviation from a straight line relationship with pressure, using end point method, over the specified
pressure range.
•
Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is
cycled to and from the minimum or maximum operating temperature points, with zero differential pressure
applied.
•
Pressure Hysteresis:
Output deviation at any pressure within the specified range, when this pressure is cycled to and from the
minimum or maximum rated pressure, at 25°C.
•
•
TcSpan:
TcOffset:
Output deviation at full rated pressure over the temperature range of 0 to 85°C, relative to 25°C.
Output deviation with minimum rated pressure applied, over the temperature range of 0 to 85°C, relative
to 25°C.
6. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to
a specified step change in pressure.
7. Common mode pressures beyond specified may result in leakage at the case–to–lead interface.
8. Exposure beyond these limits may cause permanent damage or degradation to the device.
9. Offset stability is the product’s output deviation when subjected to 1000 hours of Pulsed Pressure, Temperature Cycling with Bias Test.
2
Motorola Sensor Device Data