Table 4. Performance Specifications (At 25 C [77 F] and at rated excitation unless otherwise specified.)
Parameter
Characteristic
Response time
2 ms
Accuracy1:
>100 psi
±0.25% FSS
±0.50% FSS
<100 psi
Total error band2:
Gage:
<300 psig
>300 psig
±3% FSS
±2% FSS
Seal gage:
>300 psis
±2% FSS
Seal gage without L, M, P termination:
100 psis to 299 psis (-40 °C to 85 °C [-40 °F to 185 °F])
100 psis to 299 psis (>85 °C to 125 °C [>185 °F to 257 °F])
>300 psis (-40 °C to 125 °C [-40 °F to 257 °F])
Seal gage with L, M, P termination:
100 psis to 299 psis (-40 °C to 65 °C [-40 °F to 149 °F])
100 psis to 299 psis (>65 °C to 125 °C [>149 °F to 257 °F])
>300 psis (-40 °C to 65 °C [-40 °F to 149 °F])
>300 psis (>65 °C to 125 °C [>149 °F to 257 °F])
±3% FSS
±10% FSS
±2% FSS
±10% FSS
±15% FSS
±5% FSS
±15% FSS
Notes:
1. Includes pressure non-linearity (BFSL), pressure hysteresis and non-repeatability. Thermal errors are not included.
2. Includes zero error, span error, thermal effect on zero, thermal effect on span, thermal hysteresis, pressure-non-linearity,
pressure hysteresis and non-repeatability.
Figure 2. Operating and Temperature Compensated Area
for All Regulated Output Options
Figure 3. Operating and Temperature Compensated Area for
4 mA to 20 mA Output
125
120
115
110
105
100
95
90
85
80
75
10 Ohm
Load
250 Ohm
Load
125
124
123
122
Operating and Temperature
121
120
119
118
117
116
Compensated Area for
Regulated Output
Operating and Temperature
Compensated Area for 4 mA
to 20 mA Output
70
65
60
6
8
10 12 14 16 18 20 22 24 26 28 30
6
8
10 12 14 16 18 20 22 24 26 28 30
Supply Voltage (Vdc)
Supply Voltage (Vdc)
Note:
Note:
The operating area is extended with a 250 Ohm resistor.
Higher loads extend the operating area. The dashed line
indicates the operating and temperature compensated area
with a 24 V supply using a 250 Ohm load.
The dashed line indicates the operating and temperature
compensated area with a 24 V supply.
Figure 4. Mounting Dimensions (For reference only. mm/(in).)
Pin and Wire Codes (Option B – Packard)
Pin
a
Voltage
+ excitation
output
Current
+ excitation
- excitation
no connection
b
c
common
A variety of pressure ports and electrical
termination connection options are available.
Refer to the “How to Order” on previous page for
possible combinations. Contact your Honeywell
representative for details.
Honeywell Sensing and Control