SpecNo.JELF243A-0142C-01
P.1/8
Reference Only
CHIP COIL(CHIP INDUCTORS)LQH2MPN□□□□GRL REFERENCE SPECIFICATION
1. Scope
This reference specification applies to LQH2MPN_GR series, Chip coil (Chip Inductors).
2. Part Numbering
(ex) LQ
Product ID Structure Dimension Applications Category Inductance Tolerance Dimension Other Packaging
H
2M
(L×W)
P
N
100
M
G
R
L
and
(T)
L:Taping
Characteristics
3. Rating
・Operating Temperature Range.
(Ambient temperature; Self-temperature rise is not included)
(Product temperature; Self- temperature rise is included)
-40 to +105°C
-40 to +125°C
・Storage Temperature Range.
-40 to +105°C
Rated Current(mA)
Inductance
Self
Resonant
Frequency
(MHz min)
∗2 Based on
Temperature rise
DC
Resistance
(Ω)
Customer
Murata
∗1 Based on
inductance
change
Part Number
Part Number
∗3 Ambient
∗4 Ambient
temperature
(105℃)
Tolerance
(µH)
temperature
(%)
(85℃)
LQH2MPNR33NGRL
LQH2MPNR47NGRL
LQH2MPN1R0NGRL
LQH2MPN1R5NGRL
LQH2MPN2R2MGRL
LQH2MPN3R3MGRL
LQH2MPN4R7MGRL
LQH2MPN6R8MGRL
LQH2MPN100MGRL
LQH2MPN150MGRL
LQH2MPN220MGRL
LQH2MPN330MGRL
LQH2MPN470MGRL
LQH2MPN680MGRL
LQH2MPN820MGRL
0.33
0.47
1.0
1.5
2.2
3.3
4.7
6.8
10
0.15±20%
0.18±20%
0.25±20%
0.32±20%
0.39±20%
0.47±20%
0.60±20%
0.72±20%
0.88±20%
1.7±20%
2.1±20%
4.3±20%
5.3±20%
6.7±20%
7.3±20%
130
120
100
60
50
45
40
35
30
25
20
15
10
7
2200
1950
1550
1330
1180
1020
870
1130
1060
900
790
680
640
580
530
480
340
290
200
180
160
150
670
630
540
470
400
380
340
310
280
200
170
120
110
100
90
N:±30%
730
610
15
M:±20%
490
22
410
33
310
47
270
68
230
82
5
210
∗1: When applied Rated current to the Products, Inductance will be within ±30% of intial inductance value range .
∗2: Keep the temperature(ambient temperature plus self-generation of heat) under 125℃.
∗3: When applied rated current to the Products, temperature rise caused by self-generated heat shall be limited to 40℃ max.
(Ambient temperature 85℃).
∗4: When applied rated current to the Products,temperature rise caused by self-generated heat shall be limited to 20℃ max.
(Ambient temperature 85-105℃).
4. Testing Conditions
《Unless otherwise specified》
Temperature : Ordinary Temperature (15 to 35°C)
Humidity : Ordinary Humidity (25 to 85 % (RH))
《In case of doubt》
Temperature
Humidity
: 20 ± 2°C
: 60 to 70 % (RH)
Atmospheric Pressure : 86 to 106 kPa
MURATA MFG.CO., LTD