Spec No.: JELF243B_9101M-01  
P5/12  
7. Electrical Performance  
No.  
Item  
Specification  
Meet chapter 3 ratings.  
Meet chapter 3 ratings.  
Test method  
Measuring equipment: Keysight E4991A or the  
equivalent  
7.1 Inductance  
7.2 Q  
Measuring frequency: 100 MHz  
Measuring conditions:  
Measurement signal level: Approx. 0 dBm  
Measurement terminal distance: 0.5 mm  
Electrical length: 10 mm  
Weight: Approx. 1 N to 5 N  
Measuring fixture: Keysight 16197A  
Position the chip coil under test as shown in the  
measuring example below and connect it to the  
electrode by applying weight.  
Measurement example:  
Measuring method: see "Electrical performance:  
Measuring method for inductance/Q" in the Appendix.  
Measuring equipment: digital multimeter  
Measuring equipment: Keysight 8753C or the  
equivalent  
7.3 DC resistance  
7.4 Self-resonant  
frequency  
Meet chapter 3 ratings.  
Meet chapter 3 ratings.  
7.5 Rated current  
Product temperature rise: 25°C max.  
Apply the rated current specified in chapter 3.  
8. AEC-Q200 Requirement  
8.1 Performance [based on table 5 for magnetics (inductors/transformer) AEC-Q200 Rev. D issued June 1,  
2010]  
AEC-Q200  
Murata specification/deviation  
No.  
3
Stress  
Test method  
1000 h at 125°C  
Set for 24 h at room condition, then  
measured.  
High  
Meet table A after testing.  
Table A  
temperature  
exposure  
Appearance  
No damage  
Inductance change rate (at 100 MHz) Within ±10%  
4
Temperature  
cycling  
1000 cycles  
-40°C to +125°C  
Meet table A after testing.  
Set for 24 h at room condition, then  
measured.  
7
8
9
Biased humidity 1000 h at 85°C, 85% (RH). Unpowered. Meet table A after testing.  
Set for 24 h at room condition, then  
measured.  
Operational life Apply 125°C 1000 h  
Set for 24 h at room condition, then  
Meet table A after testing.  
measured.  
External visual Visual inspection  
No abnormalities  
No defects  
10 Physical  
dimension  
Meet chapter 5, "Appearance and  
Dimensions".  
12 Resistance to  
solvents  
Per MIL-STD-202  
Method 215  
Not applicable  