5秒后页面跳转
LNK414EG PDF预览

LNK414EG

更新时间: 2022-11-14 09:20:31
品牌 Logo 应用领域
帕沃英蒂格盛 - POWERINT 驱动器
页数 文件大小 规格书
20页 2117K
描述
LinkSwitch-PH LED Driver IC Family

LNK414EG 数据手册

 浏览型号LNK414EG的Datasheet PDF文件第1页浏览型号LNK414EG的Datasheet PDF文件第2页浏览型号LNK414EG的Datasheet PDF文件第3页浏览型号LNK414EG的Datasheet PDF文件第5页浏览型号LNK414EG的Datasheet PDF文件第6页浏览型号LNK414EG的Datasheet PDF文件第7页 
LNK403-409/413-419  
Over-Current Protection  
The current limit circuit senses the current in the power FET.  
When this current exceeds the internal threshold (ILIMIT), the power  
FET is turned off for the remainder of that cycle. A leading edge  
blanking circuit inhibits the current limit comparator for a short  
time (tLEB) after the power FET is turned on. This leading edge  
blanking time has been set so that current spikes caused by  
capacitance and rectifier reverse recovery will not cause  
premature termination of the power FET conduction.  
D
S
V
CONTROL  
BP  
R
FB  
Line Under/Overvoltage Protection  
This device includes both line under- and overvoltage detection  
to limit the minimum start-up and maximum operating voltage  
detected through the VOLTAGE MONITOR pin. An external peak  
detector consisting of a diode and capacitor are required to  
provide input line peak voltage to the VOLTAGE MONITOR pin  
through a resistor. At power up, IUV+ keeps the LinkSwitch-PH  
off until the input line voltage reaches the undervoltage threshold.  
At power down, IUV- prevents restart attempts after the output  
goes out of regulation.  
PI-5435-052510  
Figure 6. Remote ON/OFF VOLTAGE MONITOR pin Control  
5.9 V Regulator/Shunt Voltage Clamp  
The internal 5.9 V regulator charges the bypass capacitor  
connected to the BYPASS pin to 5.9 V by drawing a current  
from the voltage on the DRAIN pin whenever the power FET is  
off. The BYPASS pin is the internal supply voltage node. When  
the power FET is on, the device operates from the energy  
stored in the bypass capacitor. Extremely low power  
consumption of the internal circuitry allows LinkSwitch-PH  
to operate continuously from current it takes from the DRAIN  
pin. A bypass capacitor value of 10 or 100 mF is sufficient for  
both high frequency decoupling and energy storage. In  
addition, there is a 6.4 V shunt regulator clamping the BYPASS  
pin at 6.4 V when current is provided to the BYPASS pin  
through an external resistor. This facilitates powering of  
LinkSwitch-PH externally through a bias winding to increase  
operating efficiency. It is recommended that the BYPASS pin is  
supplied current from the bias winding for normal operation.  
The same resistor used for UV also sets line overvoltage (OV)  
shutdown threshold which, once exceeded, forces the  
LinkSwitch-PH to stop switching (after completion of the current  
switching cycle). Once the line voltage returns to normal, the  
device resumes normal operation. A small amount of hysteresis  
is provided on the OV threshold to prevent noise triggering.  
When the power FET is off, the rectified DC high voltage surge  
capability is increased to the voltage rating of the power FET  
(725 V), due to the absence of the reflected voltage and leakage  
spikes on the drain.  
Hysteretic Thermal Shutdown  
The thermal shutdown circuitry senses the controller die  
temperature. The threshold is set at 142 °C typical with a 75 °C  
hysteresis. When the die temperature rises above this threshold  
(142 °C) the power FET is disabled and remains disabled until  
the die temperature falls by 75 °C, at which point the power FET  
is re-enabled.  
Auto-Restart  
In the event of an open-loop fault (open FEEDBACK pin resistor  
or broken path to feedback winding), output short-circuits or an  
overload condition the controller enters into the auto-restart  
mode. The controller annunciates both short-circuit and  
open-loop conditions once the FEEDBACK pin current falls  
below the IFB(AR) threshold after the soft-start period. To  
minimize the power dissipation under this fault condition the  
shutdown/auto-restart circuit turns the power supply on (same  
as the soft-start period) and off at an auto-restart duty cycle of  
typically DCAR for as long as the fault condition persists. If the  
fault is removed during the auto-restart off-time, the power  
supply will remain in auto-restart until the full off-time count is  
completed. Special consideration must be made to appropriately  
size the output capacitor to ensure that after the soft-start  
period (tSOFT) the FEEDBACK pin current is above the IFB(AR)  
threshold to ensure successful power-supply start-up.  
After the soft-start time period, auto-restart is activated only  
Safe Operating Area (SOA) Protection  
The device also features a safe operating area (SOA) protection  
mode which disables FET switching for 40 cycles in the event  
the peak switch current reaches the ILIMIT threshold and the  
switch on-time is less than tON(SOA). This protection mode  
protects the device under short-circuited LED conditions and at  
start-up during the soft-start period when auto-restart protection  
is inhibited. The SOA protection mode remains active in normal  
operation.  
when the FEEDBACK pin current falls below IFB(AR)  
.
4
Rev. D 08/11  
www.powerint.com  

与LNK414EG相关器件

型号 品牌 描述 获取价格 数据表
LNK414LG POWERINT LinkSwitch-PH LED Driver IC Family

获取价格

LNK415 POWERINT LinkSwitch-PH LED Driver IC Family

获取价格

LNK415EG POWERINT LinkSwitch-PH LED Driver IC Family

获取价格

LNK415LG POWERINT LinkSwitch-PH LED Driver IC Family

获取价格

LNK416 POWERINT LinkSwitch-PH LED Driver IC Family

获取价格

LNK416EG POWERINT LinkSwitch-PH LED Driver IC Family

获取价格