5秒后页面跳转
LNK363DN PDF预览

LNK363DN

更新时间: 2022-09-29 19:46:59
品牌 Logo 应用领域
帕沃英蒂格盛 - POWERINT /
页数 文件大小 规格书
16页 783K
描述
IC OFFLINE SWIT HV 8SOIC

LNK363DN 数据手册

 浏览型号LNK363DN的Datasheet PDF文件第4页浏览型号LNK363DN的Datasheet PDF文件第5页浏览型号LNK363DN的Datasheet PDF文件第6页浏览型号LNK363DN的Datasheet PDF文件第8页浏览型号LNK363DN的Datasheet PDF文件第9页浏览型号LNK363DN的Datasheet PDF文件第10页 
LNK362-364  
TOP VIEW  
Y1-  
Capacitor  
Input Filter  
Capacitor  
D
S
S
T
r
a
n
s
f
FB  
S
S
BP  
o
r
m
e
r
-
+
HV DC  
INPUT  
CBP  
Opto-  
coupler  
Maximize hatched copper  
areas (  
) for optimum  
heatsinking  
Output Filter  
Capacitor  
DC  
OUT  
-
+
PI-4585-021607  
Figure 7. Recommended Printed Circuit Layout for LinkSwitch-XT using D Package in a Flyback Converter Conguration.  
capacitor should be minimized. In addition, sufcient copper  
area should be provided at the anode and cathode terminals  
of the diode for heat sinking. A larger area is preferred at the  
quiet cathode terminal. A large anode area can increase high  
frequency radiated EMI.  
saturationandexcessiveleading-edgecurrentspikesatstartup.  
Repeatundersteadystateconditionsandverifythattheleading-  
edge current spike event is below ILIMIT(MIN) at the end of the  
tLEB(MIN). Under all conditions, the maximum drain current  
should be below the specied absolute maximum ratings.  
3. Thermal Check – At specied maximum output power,  
minimuminputvoltageandmaximumambienttemperature,  
verify that the temperature specications are not exceeded  
for LinkSwitch-XT, transformer, output diode and output  
capacitors. Enough thermal margin should be allowed for  
part-to-part variation of the RDS(ON) of LinkSwitch-XT as  
speciedinthedatasheet.Underlowline,maximumpower,  
a maximum LinkSwitch-XT SOURCE pin temperature of  
105 °C is recommended to allow for these variations.  
Quick Design Checklist  
As with any power supply design, all LinkSwitch-XT designs  
should be veried on the bench to make sure that component  
specicationsarenotexceededunderworst-caseconditions.The  
following minimum set of tests is strongly recommended:  
1. Maximum drain voltage – Verify that VDS does not exceed  
650Vatthehighestinputvoltageandpeak(overload)output  
power. The 50 V margin to the 700 V BVDSS specication  
gives margin for design variation, especially in Clampless  
designs.  
2. Maximumdraincurrent–Atmaximumambienttemperature,  
maximum input voltage and peak output (overload) power,  
verify drain current waveforms for any signs of transformer  
Design Tools  
Up-to-date information on design tools can be found at the  
Power Integrations web site: www.powerint.com.  
7
Rev. E 11/08  

与LNK363DN相关器件

型号 品牌 描述 获取价格 数据表
LNK363DN-TL POWERINT IC OFFLINE SWIT HV 8SOIC

获取价格

LNK363G POWERINT Energy Effi cient, Low Power Off-Line Switcher IC