5秒后页面跳转
LM555-MIL PDF预览

LM555-MIL

更新时间: 2022-10-12 16:34:18
品牌 Logo 应用领域
德州仪器 - TI /
页数 文件大小 规格书
21页 1312K
描述
LM555-MIL Timer

LM555-MIL 数据手册

 浏览型号LM555-MIL的Datasheet PDF文件第4页浏览型号LM555-MIL的Datasheet PDF文件第5页浏览型号LM555-MIL的Datasheet PDF文件第6页浏览型号LM555-MIL的Datasheet PDF文件第8页浏览型号LM555-MIL的Datasheet PDF文件第9页浏览型号LM555-MIL的Datasheet PDF文件第10页 
LM555  
www.ti.com  
SNAS548C FEBRUARY 2000REVISED MARCH 2013  
APPLICATIONS INFORMATION  
MONOSTABLE OPERATION  
In this mode of operation, the timer functions as a one-shot (Figure 12). The external capacitor is initially held  
discharged by a transistor inside the timer. Upon application of a negative trigger pulse of less than 1/3 VCC to  
pin 2, the flip-flop is set which both releases the short circuit across the capacitor and drives the output high.  
Figure 12. Monostable  
The voltage across the capacitor then increases exponentially for a period of t = 1.1 RA C, at the end of which  
time the voltage equals 2/3 VCC. The comparator then resets the flip-flop which in turn discharges the capacitor  
and drives the output to its low state. Figure 13 shows the waveforms generated in this mode of operation. Since  
the charge and the threshold level of the comparator are both directly proportional to supply voltage, the timing  
interval is independent of supply.  
VCC = 5V  
Top Trace: Input 5V/Div.  
TIME = 0.1 ms/DIV.  
RA = 9.1kΩ  
Middle Trace: Output 5V/Div.  
Bottom Trace: Capacitor Voltage 2V/Div.  
C = 0.01μF  
Figure 13. Monostable Waveforms  
During the timing cycle when the output is high, the further application of a trigger pulse will not effect the circuit  
so long as the trigger input is returned high at least 10μs before the end of the timing interval. However the circuit  
can be reset during this time by the application of a negative pulse to the reset terminal (pin 4). The output will  
then remain in the low state until a trigger pulse is again applied.  
When the reset function is not in use, it is recommended that it be connected to VCC to avoid any possibility of  
false triggering.  
Figure 14 is a nomograph for easy determination of R, C values for various time delays.  
NOTE  
In monostable operation, the trigger should be driven high before the end of timing cycle.  
Copyright © 2000–2013, Texas Instruments Incorporated  
Submit Documentation Feedback  
7
Product Folder Links: LM555  
 
 

与LM555-MIL相关器件

型号 品牌 描述 获取价格 数据表
LM555MW8 NSC IC PULSE; RECTANGULAR, TIMER, UUC, WAFER, Analog Waveform Generation Function

获取价格

LM555MWC TI PULSE; RECTANGULAR, TIMER, UUC, WAFER

获取价格

LM555MWC NSC IC PULSE; RECTANGULAR, TIMER, UUC, WAFER, Analog Waveform Generation Function

获取价格

LM555-MWC TI Highly Stable 555 Timer 0-WAFERSALE -40 to 85

获取价格

LM555N HARRIS Timers for Timing Delays and Oscillator Application in Commercial, Industrial and Military

获取价格

LM555QML TI LM555QML Timer

获取价格