HO-NP/SP33-1000 SERIES  
Absolute maximum ratings  
Parameter  
Symbol  
UC  
Unit  
V
Value  
3.3  
Supply voltage (not operating)  
TB  
°C  
120  
Primary conductor temperature  
ESD rating, Human Body Model (HBM)  
UESD  
kV  
2
Stresses above these ratings may cause permanent damage. Exposure to absolute maximum ratings for extended periods may  
degrade reliability.  
UL 508: Ratings and assumptions of certification  
File # E189713 Volume: 2 Section: 5  
Standards  
CSA C22.2 NO. 14-10 INDUSTRIAL CONTROL EQUIPMENT - Edition 11 - Revision Date 2011/08/01  
UL 508 STANDARD FOR INDUSTRIAL CONTROL EQUIPMENT - Edition 17 - Revision Date 2010/04/15  
Ratings  
Parameter  
Symbol  
Unit  
Value  
Primary involved potential  
V AC/DC  
600  
Max surrounding air temperature  
TA  
°C  
105  
According to series primary  
currents  
Primary current  
IP  
A
Secondary supply voltage  
Output voltage  
UC  
V DC  
3.3  
Vout  
V
0 to 3.3  
Conditions of acceptability  
When installed in the end-use equipment, consideration shall be given to the following:  
1 - These devices have been evaluated for overvoltage category III and for use in pollution degree 2 environment.  
2 - A suitable enclosure shall be provided in the end-use application.  
3 - The terminals have not been evaluated for field wiring.  
4 - These devices have been evaluated for use in 105°C maximum surrounding air temperature.  
5 - The secondary (Sensing) circuit is intended to be supplied by a Isolated Secondary Circuit - Limited voltage circuit defined  
by UL 508 paragraph 32.5. The maximum open circuit voltage potential available to the circuit and overcurrent protection  
shall be evaluated in the end use application.  
6 - These devices are intended to be mounted on a printed wiring board of end-use equipment. The suitability of the connec-  
tions (including spacings) shall be determined in the end-use application.  
7 - Primary terminals shall not be straightened since assembly of housing case depends upon bending of the terminals.  
8 - Any surface of polymeric housing have not been evaluated as insulating barrier.  
9 - Low voltage circuits are intended to be powered by a circuit derived from an isolating source (such as a transformer, optical  
isolator, limiting impedance or electro-mechanical relay) and having no direct connection back to the primary circuit (other  
than through the grounding means).  
Marking  
Only those products bearing the UL or UR Mark should be considered to be Listed or Recognized and covered under UL's  
Follow-Up Service. Always look for the Mark on the product.  
Page 2/15  
17September2013/Version 2 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice  
www.lem.com  

与HO15-NP-0202相关器件

型号 品牌 描述 获取价格 数据表
HO15-NP-0203 LEM Current Transducer

获取价格

HO15-NP-0204 LEM Current Transducer

获取价格

HO15-NP-0205 LEM Current Transducer

获取价格

HO15-NP-0206 LEM Current Transducer

获取价格

HO15-NP-0207 LEM Current Transducer

获取价格

HO15-NP-020A LEM Current Transducer

获取价格