Operation in -5.2 V Designs
Electromagnetic Interference (EMI)
For applications that require -5.2 V dc power supply level
for true ECL logic circuits, the HFBR/HFCT-5208M transceiver
One of a circuit board designer’s foremost concerns is the
control of electromagnetic emissions from electronic
can be operated with a V = 0 V dc and a V = -5.2 V dc. equipment. Success in controlling generated
CC
EE
This transceiver is not specified with an operating, negative Electromagnetic Interference (EMI) enables the designer to
power supply voltage. The potential compromises that can pass a governmental agency’s EMI regulatory standard; and
occur with use of -5.2 V dc power are that the absolute more importantly, it reduces the possibility of interference
voltage states for V and V will be changed slightly due
to the 0.2 V difference in supply levels. Also, noise immunity
may be compromised for the HFBR/HFCT-5208M trans-
to neighboring equipment. There are three options
available for the HFBR/HFCT-5208M with regard to EMI
shielding for providing the designer with a means to
OH
OL
ceiver because the ground plane is now the V supply achieve good EMI performance. The EMI performance of
CC
point. The suggested power supply filter circuit shown in an enclosure using these transceivers is dependent on the
the Recommended Circuit Schematic figure should be
chassis design. Avago Technolgies encourages using
located in the V paths at the transceiver supply pins. Direct standard RF suppression practices and avoiding poorly EMI-
EE
coupling of the differential data signal can be done between
sealed enclosures. In addition, Avago Technolgies advises
the HFBR-5208M transceiver and the standard ECL circuits. that for the best EMI performance, the metalized case must
For guaranteed -5.2 V dc operation, contact your local be connected to chassis ground using one of the shield
Avago Technolgies Component Field Sales Engineer for
options.
assistance.
HFBR/HFCT-5208EM transceiver beyond the front surface
of the panel or enclosure is 6.35 mm (0.25 in) . With this
option, there is flexibility of positioning the module to fit
the specific need of the enclosure design. (See Figure 8 for
the mechanical drawing dimensions of this shield.)
20.32
(0.800)
2 x 1.9 – 0.1
(0.075 – 0.004)
The second shielded option, option FM, is for applications
that are designed to have a flush mounting of the module
with respect to the front of the panel or enclosure. The
flush-mount design accommodates a large variety of panel
thickness, i.e. 1.02 mm (.04 in) min to 2.54 mm (0.1 in)
max. Note the reference plane for the flush-mount design
is the interior side of the panel or enclosure. The
recommended distance from the centerline of the
transceiver front solder posts to the inside wall of the panel
is 13.82 mm (0.544 in) . This option contacts the inside
panel or enclosure wall on all four sides of this metal shield.
(See Figure 10 for the mechanical drawing dimensions of
this shield.)
9 x 0.8 – 0.1
(0.032 – 0.004)
20.32
(0.800)
2.54
(0.100)
TOP VIEW
DIM ENSIONS ARE IN M ILLIM ETERS (INCHES)
Figure 5. Recommended Board Layout Pattern
Figure 6. 622.08 Mb/s OC-12 ATM-SONET/SDH Reference Design Board
5