H HiTRON
Universal input harmonic correction (PFC) AC-DC Medical & ITE application
external desktop switching adapter 200-250 Watts green power
single output HEMP252G series
Features
ꢀ
ꢀ
ꢀ
Energy Efficiency Level V
Medical and ITE application
Wide operating temperature range and
high efficiency
ꢀ
ꢀ
Class I construction
CE marking compliance
Specification
Input
Protection
Input Voltage
Input Frequency
Input Current
90-264VAC
Over Load
Typical set at about 110-150% of
rating output wattage
47-63Hz
Typical 1.95A at 115VAC
Typical 1.05A at 230VAC
15.8Arms at 230VAC
Typical 0.96-0.99 at full load
3 pole IEC320-C14(DT7)
Less than 0.3mA
General
Efficiency
Typical 88-94% (depending on model)
85-100KHz
Inrush Current
Power Factor
Switching Frequency
Dielectric Withstand
Circuit Topology
Transient Response
IEC60601-1 and IEC60950-1
Half-Bridge Circuit
Input Connector
Earth Leakage Current
No Load Power
Output
Output voltage returns in less than
1mS following a 25% load change
3.62-4.54W / Cubic Inch
Less than 0.5W
Power Density
Output Connector/Plug
Line Regulation
Load Regulation
Total Regulation
Noise & Ripple
Adjustability
Optional
Environmental
Operating Temperature
Storage Temperature
Cooling
Typical ±0.1%
-25°C to +40°C
-30°C to +85°C
Convection-cooled
5000m
Typical ±3%
Typical ±5%
Typical 1% peak to peak
Factory set
Operating Altitude
Operating Humidity
Storage Humidity
10-95% RH, non-condensing
5-95% RH
Hold-up Time
Typical 25mS at 115VAC
Protection
Over Voltage
Safety/EMC
Emissions
Built-in (Latch)
EN55011 and EN55022 FCC Class B
IEC61000-3-2
Over Temperature
Installed by NTC
Harmonic Current
Safety Standard
IEC60601-1 and IEC60601-1 Class I
Notes:
(1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115VAC or 230VAC in percentage to indicate the change in output voltage as the load varied from half load to full load ( %).
(3) The exact obtainable load regulation depends upon the output cord selected and load current.
(4) Derating is needed under low input voltages 90-110Vac. Please refer to the Input Voltage Derating for more details.
(5) Due to requests in market and advances in technology, specifications subject to change without notice
Edited on March 30, 2016
-1-