OCXO HCMOS Output
HCD361
Specifications
Product
HCD361
Option
Codes
Parameters
Frequency range: 5.0 ~ ±0.0MHz
Ageing per day (at despatch):
< ±1ꢀ10-9
˿
˿
D
E
F
< ±5ꢀ10-10
< ±±ꢀ10-10
Frequency stability:
< ±5ꢀ10-8 per year
< ±1ꢀ10-9 per 10% change in VDD
36.10 (max)
27.20 (max)
Short term stability:
< ±1ꢀ10-11 over 1 sec
19.40
(max)
Temperature stability: < ±±ꢀ10-8
˿
˿
P
R
S
< ±1ꢀ10-8
< ±5ꢀ10-9
0.50
5.00
0.80Ø
17.80
25.40
Operating temperature range:
0 to +50°C
15.00
˿
˿
A
C
F
-10 to +60°C
-±0 to +70°C
PIN
1
CONNECTION
Freq adjustment
Ref voltage out
Supply
3
2
1
4
5
Storage temperature range:
8.90
8.90
2
-40 to +90°C
3
Output waveform:
4
RF output
HCMOS / TTL compatible
5
Ground & case
Frequency adjustment:
±5ꢀ10-7 (typ) over +0.5 to +7.0V
(sufficient for 10 years ageing min)
Stabilised +7.0V supply provided
BOTTOM VIEW
Scale 1:1
Features
Supply voltage (VDD):
+1±V (±0.5V)
˿
˿
N
P
R
+15V (±0.5V)
+18V (±0.5V)
«
«
«
«
«
Temperature stability down to 5ppb
Single 12V supply (15v or 18V optional)
Compact package
Power consumption:
5.0W maꢀ at switch on
1.±W typ when stabilised at ±5°C
Warm up:
Standard European IEC CO-08 pin-out
Custom options available
< ±1ꢀ10-8 after 10mins at +±0°C
Phase noise (@ 10#0MHz):
< -1±5 dBc/Hz @ 10Hz
< -135 dBc/Hz @ 100Hz
< -150 dBc/Hz @ 1kHz
< -155 dBc/Hz @ 10kHz
< -155 dBc/Hz @ 50kHz
Standard Models
The table shows the most common models. In most cases
selecting one of these models will ensure the best combina-
tion of price / performance and availability.
Harmonics:
Shock:
< -30dB wrt carrier
IEC 68-±-±7 Test Ea
50G for 11ms
Freq
Specification Ageing
per day
Temperature
stability
Part No
Vibration:
IEC 68-±-06 Test Fc
10-55Hz, 1.5mm. 55-500Hz, 10G
5.0MHz HCD361/DPFN ±1ꢀ10-9
5.0MHz HCD361/ERFN ±5ꢀ10-10 ±1ꢀ10-8 -±0+70°C MS06944
10.0MHz HCD361/DPFN ±1ꢀ10-9 ±±ꢀ10-8 -±0+70°C MS06941
10.0MHz HCD361/ERFN ±5ꢀ10-10 ±1ꢀ10-8 -±0+70°C MS06943
±±ꢀ10-8 -±0+70°C MS0694±
Standard. ˿ Optional - Please specify required code(s) when ordering
Ordering Information
Part No, or product name + option codes + frequency
eg: HCD361/DPFN 10#0MHz
HCD361/ERFN 5#0MHz
Option code X (eg HCD361/X) denotes a custom specification.
Tel: +44 1460 256 100
Faꢀ: +44 1460 256 101
E-mail: sales@golledge#com
Web: www#golledge#com