HA17555 Series
Absolute Maximum Ratings
(Ta = 25°C)
Unit
Item
Supply voltage
Symbol
HA17555PS/FP
18
HA17555/F
18
VCC
V
Discharge current
IT
200
200
200
200
200
200
mA
mA
mA
mW
°C
Output source current
Output sink current
Power dissipation*1
Operating temperature
Storage temperature
Isource
Isink
PT
Topr
Tstg
600/385
–20 to +75
–55 to +125
600/385
–20 to +70
–55 to +125
°C
Note: 1. For the HA17555/PS,
This value applies up to Ta = 50°C; at temperatures above this, 8.3mW/°C derating should be applied.
For the HA17555F/FP,
This value applies up to Ta = 25°C; at temperatures above this, 3.85mW/°C derating should be applied.
See notes on SOP Package Usage in Reliability section.
a. HA17555PS
b. HA17555FP
0.7
a. 0.6 W
0.6
8.3 mW/°C
0.5
3.85 mW/°C
b. 0.385 W
0.4
0.3
0.2
0.1
–40 –20
0
20 40 60 7080 100 120
Ambient Temperature Ta (°C)
a. HA17555
b. HA17555F
0.7
a. 0.6 W
0.6
0.5
0.4
0.3
0.2
0.1
8.3 mW/°C
3.85 mW/°C
b. 0.385 W
–40 –20
0
20 40 60 7080 100 120
Ambient Temperature Ta (°C)
Rev.1.00 Jun 15, 2005 page 3 of 7