GP1FB201RK
Fig.2 Measuring Method of Output Voltage and Pulse Response
Fiber optic cable
Standard transmitter
GP1FB201RK Unit to be measured
GND Vout
VCC
Vin
VCC GND
VCC
2.5V
Input
6Mbps NRZ, Duty 50%
CH1
CH2
Tektronix 7834
or 7934 type
Oscilloscope
Test item
Standard transmitter
Input signal
(CH1)
Test item
Symbol
50%
Low → High pulse delay time
High → Low pulse delay time
Rise time
tpLH
tpHL
tr
tr
tf
Fall time
tf
VOH
Pulse width distortion
∆tw=tpHL−tpLH
90%
50%
10%
GP1FB201RK
Output signal
(CH2)
∆tw
High level output voltage
VOH
VOL
Low level output voltage
Notes (1) VCC=2.5±0.05V (State of operating)
VOL
tpLH
tpHL
(2) The fiber coupling light output set at −14.5dBm/−24.0dBm.
(3) The probe for the oscilloscope must be more than 1MΩ and less than 10pF.
(4) The output (H/L level) of GP1FB201RK are not fixed constantly when it receives
the modulating light (including DC light, no input light) less than 0.1Mbps.