GP1FAV55TK0F
■Measurement Method
Fig. 1 Output Optical Power Coupled Into Fiber
Standard fiber optic cable
GP1FAV55TK0F
Device under test
Optical power meter
(Anritsu) ML93B
Vin
Vcc
GND
Vcc
The optical power meter must be
calibrated to 660 nm. (0 dBm = 1 mW)
D
Notes
1. Vcc = 5.0 V (State of operating)
2. To bundle up the standard fiber optic cable, make it into a loop with the diameter D = 10 cm or more.
(The standard fiber optic cable will be specified elsewhere.)
Fig. 2 Input Voltage and Supply Current
Standard fiber optic cable
GP1FAV55TK0F
Optical power meter
Device under test
(Anritsu) ML93B
Vin
Vcc
GND
Vcc
The optical power meter must be
calibrated to 660 nm. (0 dBm = 1 mW)
Icc
Vin
Input conditions and judgment method
No.
1
Input conditions
Judgment method
≤
≤
Vin = 2.0 V or more -21 PC -15 dBm, ICC = 13 mA or less
≤
Vin = 0.8 V or less
PC -36 dBm, ICC = 13 mA or less
2
Notes
Vcc = 5.0 V (State of operating)
Sheet No.: E2-A00701EN
4