G70D
G70D
Specifications
3 RATINGS
Power MOSFET Relay (G3DZ) Specifications
The following values apply to the G3DZ Relay mounted to the
G70D and do not apply to the G3DZ Relay itself before it is
mounted.
The following values apply to the G6D Relay mounted to the
G70D and do not apply to the G6D Relay itself before it is
mounted.
Input Ratings
Electromechanical Relay (G6D) Specifications
Coil Ratings
Rated voltage
Operating voltage
Voltage level
24 VDC
19.2 to 28.8 VDC
19.2 VDC max.
1 VDC min.
Rated voltage
24 VDC
10.5 mA
Must operate
Must release
Rated current
Coil resistance
2,880
Ω
Input impedance
Rated current
4 k
20%
Ω ±
8.2 mA 20%
Must operate voltage
Release voltage
Max. allowable voltage
Power consumption
70% max. of rated voltage
10% min. of rated voltage
130% of rated voltage
Approx. 200 mW
±
Note: The rated current includes the current consumption of the
operation indicator.
Output Ratings
Note: 1. The must operate voltage is 75% max. of the rated
voltage if the Relay is mounted upside down.
Load voltage
Load current
Inrush current
3 to 264 VAC, 3 to 125 VDC
100 A to 0.3 A
2. Rated current and coil resistance were measured at a
µ
coil temperature of 23EC (73.4EF) with a tolerance of
6 A (10 ms)
10%.
±
3. Operating characteristics were measured at a coil tem-
perature of 23EC (73.4EF).
4. The maximum allowable voltage is the maximum value
of the allowable voltage range for the relay coil operat-
ing power supply. There is no continuous allowance.
5. The rated current includes the current consumption of
the operation indicator.
Contact Ratings
Load
Resistive load (cos = 1)
φ
Rated load
3 A at 250 VAC, 3 A at 30 VDC
5 A (See Note 1)
250 VAC, 30 VDC
5 A
Rated carry current
Max. switching voltage
Max. switching current
Max. switching capacity
1,250 VA, 150 W
5 VDC, 1 mA
Error rate (level p)
(reference value)
(see note 2)
Life expectancy
Electrical: 100,000 operations
min. (under and at the rated
load at 1,800 operations/hr)
Mechanical: 20,000,000
operations min. (at 18,000
operations/hr)
Note: 1. This value is for when the maximum 8 points are ON.
2. This value is for a switching frequency of 120 times per
minute.
3