■ Coil Ratings
Rated voltage
Rated current
Coil resistance Must operate
voltage
Must release
voltage
Maximum voltage
Rated power
consumption
3 VDC
4.5 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
33.0 mA
23.2 mA
21.1 mA
17.6 mA
11.3 mA
9.1 mA
91 Ω
80% max. of rated 10% min. of rated 150% of rated voltage Approx. 100 mW
voltage voltage
194 Ω
237 Ω
341 Ω
795 Ω
1,315 Ω
5,220 Ω
(75% max. of rated (75% max. of rated
set voltage for
latching models)
reset voltage for
latching models)
4.6 mA
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.
■ High Frequency Characteristics at 1 GHz
Isolation
20 dB min. between contacts of the same pole
30 dB min. between contacts of different poles
0.2 dB max.
Insertion loss
V.S.W.R.
1.2 max.
Maximum transmission capacity
Maximum switching capacity
3 W (See note 3)
1 W (See note 3)
Note: 1. The impedance of the measurement system is 50 Ω.
2. The above values are initial
3. These values are for a load with V.S.W.R. ≤ 1.2
■ Characteristics
Item
Single-side stable models
G6K-2F-RF(-S)
Single-winding latching models
G6KU-2F-RF(-S)
Contact resistance (See note 2.)
Operating (set) time (See note 3.)
Release (reset) time (See note 3.)
Minimum set/reset pulse time
Insulation resistance (See note 4.)
100 mΩ max.
3 ms max. (approx. 1.4 ms)
3 ms max. (approx. 1.2 ms)
3 ms max. (approx. 1.2 ms)
10 ms
3 ms max. (approx. 1.3 ms)
---
1,000 MΩ min. (at 500 VDC)
750 VAC, 50/60 Hz for 1 min
Dielectric strength
Between coil and
contacts
Between contacts of
different poles
750 VAC, 50/60 Hz for 1 min
Between contacts of the 750 VAC, 50/60 Hz for 1 min
same pole
Between ground and
coil/contacts
500 VAC, 50/60 Hz for 1 min
10 to 55 Hz, 5-mm double amplitude and 55 to 500 to 55 Hz, 300 m/s2
10 to 55 Hz, 3.3-mm double amplitude and 55 to 500 to 55 Hz, 200 m/s2
1,000 m/s2
Vibration resistance
Shock resistance
Endurance
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
750 m/s2
50,000,000 operations min. (at a switching frequency of 36,000 operations/hour)
100,000 operations min. (at a switching frequency of 1,800 operations/hour)
Operating: −40°C to 70°C (with no icing or condensation)
Operating: 5% to 85%
Ambient temperature
Ambient humidity
Weight
Approx. 0.95 g
Note: 1. The above values are initial values.
2. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
3. Values in parentheses are typical values.
4. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking the dielectric strength.
322
High Frequency Relay G6K-RF