G5V-2
General-purpose, Low-cost,
Low Signal Relay
Two-pole Relays for Signal Circults
•
•
•
General-purpose DIL terminal layout.
Wide switching power of 10 μA to 2 A.
Fully-sealed type Relays standardized with bifurcated crossbar contacts. Highly
reliable in addition to its high environment resistance.
•
•
•
Conforms to FCC Part 68 (impulse withstand voltage of 1,500 V for 10 x 160 µs
between coil and contacts and between contacts of the same polarity).
High dielectric strength at 1,000 VAC between coil and contacts, and 750 VAC
between contacts of the same polarity.
UL and CSA standard approved.
RoHS Compliant
■Model Number Legend
■Application Examples
1. Number of Poles/ Contact form 2. Classification
• Telecommunication equipment
• Security equipment
G5V-@-@
—
—
2: 2-pole/DPDT (2c)
None: Standard
H1: High-sensitivity
1
2
G
5
■Ordering Information
■Characteristics
V
Minimum
packing
unit
Item
Classification
Standard
High-sensitivity
100 m max.
7 ms max.
3 ms max.
min. (at 500 VDC)
Enclosure Contact Terminal
Rated coil
voltage
Model
Contact resistance *1
Operate time
Release time
50 m
Ω
max.
Ω
rating
form
shape
2
Classification
3 VDC
5 VDC
6 VDC
Insulation resistance *2
1,000 M
Ω
Between coil and
contacts
1,000 VAC, 50/60 Hz for 1 min
Standard
G5V-2
9 VDC
12 VDC
24 VDC
48 VDC
5 VDC
12 VDC
24 VDC
48 VDC
Dielectric
strength
Between contacts
of the same polarity
Between contacts
of different polarity
Between coil and
contacts
Between contacts
of the same polarity
750 VAC, 50/60 Hz 500 VAC, 50/60 Hz for
PCB
terminals
Fully
sealed
DPDT
(2c)
25
pcs/tube
for 1 min 1 min
1,000 VAC, 50/60 Hz for 1 min
1,500 V (10 x 160
1,500 V (10 x 160
1,500 V (10 x 160
μ
μ
μ
s)
s)
s)
High-
sensitivity
G5V-2-H1
Impulse
withstand
voltage
Note: When ordering, add the rated coil voltage to the model number.
Example: G5V-2 DC3.
Between contacts
of different polarity
Rated coil voltage
However, the notation of the coil voltage on the product case as well as
on the packing will be marked as @@ VDC.
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Destruction
Malfunction
Vibration
resistance
Destruction
Malfunction
1,000 m/s2
Shock
resistance
200 m/s2
100 m/s2
15,000,000 operations min.
(at 36,000 operations/hr)
Mechanical
AC: 100,000 operations
Durability
100,000 operations
min. (at 1,800
operations/hr)
min., DC: 300,000
operations min.
Electrical
(at 1,800 operations/hr)
Failure rate (P level) (reference
value) *3
10 μA at 10 m VDC
-25°C to 65°C
(with no icing or
condensation)
-25°C to 70°C
(with no icing or
condensation)
Ambient operating temperature
Ambient operating humidity
Weight
5% to 85%
Approx. 5 g
Note: The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1 VDC with a voltage
drop method.
*2. The insulation resistance was measured with a 500 VDC megohmmeter
applied to the same parts as those used for checking the dielectric strength.
*3. This value was measured at a switching frequency of 120 operations/min
and the criterion of contact resistance is 50 Ω. This value may vary
depending on the switching frequency and operating environment.
Always double-check relay suitability under actual operating conditions.
1