■ Coils Ratings for High-sensitivity Models
Rated voltage
5 VDC
12 VDC
20.8 mA
576 Ω
24 VDC
10.42 mA
2,304 Ω
Rated current
50.0 mA
Coil resistance
100 Ω
Must operate voltage
Must release voltage
Max. voltage
75% max. of the rated voltage
10% min. of the rated voltage
180% of rated voltage (at 23°C)
Power consumption
Approx. 250 mW
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
■ Contact Ratings
Item
Number of poles
Contact material
Load
General-purpose Models
High-capacity Models
1 pole
High-sensitivity Models
1 pole
2 poles
1 pole
Ag Alloy (Cd free)
Resistive load (cosφ=1)
Rated load
12 A at 250 VAC
12 A at 24 VDC
(See note.)
8 A at 250 VAC
8 A at 30 VDC
(See note.)
16 A at 250 VAC
16 A at 30 VDC
(See note.)
10 A at 250 VAC
10 A at 24 VDC
(See note.)
Rated carry current
12 A (See note.)
8 A (70°C)/5 A (85°C)
(See note.)
16 A (See note.)
10 A (See note.)
Max. switching voltage 440 VAC, 300 VDC
Max. switching current 12 A
8 A
16 A
10 A
Max. switching power
3,000 VA (4,000 VA)
2,000 VA
4,000 VA
2,500 VA
Note: Contact your OMRON representative for the ratings on fully sealed models.
■ Characteristics
Item
General-purpose
(High-capacity) Models
General-purpose Models
2 pole
High-sensitivity Models
Number of poles
1 pole
1 pole
Contact resistance
Operate (set) time
Release (reset) time
100 mΩ max.
15 ms max.
5 ms max.
Max. operating frequency Mechanical:18,000 operation/hr
Electrical:1,800 operation/hr at rated load
Insulation resistance
Dielectric strength
1,000 MΩ min. (at 500 VDC)
5,000 VAC, 1 min between coil and 5,000 VAC, 1 min between coil and
contacts contacts
5,000 VAC, 1 min between coil and
contacts
1,000 VAC, 1 min between contacts 2,500 VAC, 1 min between contacts of 1,000 VAC, 1 min between contacts
of same polarity
different polarity
1,000 VAC, 1 min between contacts of
same polarity
of same polarity
Impulse withstand voltage 10 kV (1.2×50 μs) between coil and contact
Vibration resistance
Destruction:10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction:10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Destruction:1,000 m/s2 (approx. 100 G)
Malfunction:100 m/s2 (approx. 10 G)
Shock resistance
Endurance (Mechanical)
Ambient temperature
20,000,000 operations (at 18,000 operations/hr)
Operating:–40°C to 85°C (with no icing)
Storage:–40°C to 85°C (with no icing)
Ambient humidity
Weight
5% to 85%
Approx. 12 g
Note: Values in the above table are the initial values.
204