Temperature measurement
Glass-encapsulated sensors
B57540G1
G1540
Reliability data according to AEC Q200, Rev. D
Test
Standard
Test conditions
∆R25/R25
(typical)
< 2%
Remarks
High temperature
exposure (storage) method 108
Operational life
MIL-STD-202, Storage at T = +125 °C
t = 1000 h
MIL-STD-202, 1000 h / +125 °C
No visible
damage
< 2%
No visible
damage
method 108
Test voltage max. 0.3 V DC on
NTC1)
Lower test temperature: ꢀ55 °C < 2%
Temperature
cycling
JESD 22,
No visible
damage
method JA-104 Upper test temperature: 125 °C
1000 cycles
Dwell time: max. 30 min at each
temperature
Transition time in air: max. 1 min
MIL-STD-202, Test leaded device integrity
method 211
Terminal strength
(leaded)
< 1%
< 1%
No visible
damage
Condition A: 2.27 N2)
Mechanical shock MIL-STD-202, Acceleration: 40 g 2)
No visible
damage
method 213,
condition C
Pulse duration: 6 ms
Number of bumps: 3, each
direction
Vibration
MIL-STD-202, Acceleration: 5 g
< 1%
No visible
damage
method 204
t = 20 min
12 cycles in each of 3 directions
Frequency range: 10 to 2000 Hz
1) Self heating of the NTC thermistor must not exceed 0.2 K, steady state. Test conditions deviating from AEC Q200, Rev. D.
2) Deviating from AEC Q200, Rev. D.
Note
Contact of NTC thermistors with any liquids and solvents shall be prevented. It must be
ensured that no water enters the NTC thermistors (e.g. through plug terminals).
Avoid dewing and condensation unless thermistor is specified for these conditions.