G084SN03 V1
2.2 Optical Characteristics
The optical characteristics are measured under stable conditions at 25 (Room Temperature):
Item
Unit
Conditions
Min.
Typ.
Max.
Note
[cd/m2]
IRCFL= 4.6mA
(center point)
White Luminance
200
220
-
1
%
Uniformity
9 Points
70
75
-
-
1, 2, 3
4
Contrast Ratio
400
600
10
[msec]
[msec]
[msec]
Rising
-
-
-
-
-
-
Response Time
Viewing Angle
Falling
5
25
35
75
75
75
Raising + Falling
[degree]
[degree]
Horizontal
CR = 10
(Right)
(Left)
-
-
-
6
[degree]
[degree]
Vertical
CR = 10
(Upper)
(Lower)
-
75
-
Red x
Red y
TBD
TBD
TBD
TBD
TBD
TBD
0.28
0.30
TBD
TBD
TBD
TBD
TBD
TBD
0.31
0.33
TBD
TBD
TBD
TBD
TBD
TBD
0.34
0.36
Green x
Green y
Blue x
Color / Chromaticity
Coordinates
(CIE 1931)
Blue y
White x
White y
Color Gamut
%
45
-
Note 1: Measurement method
Equipment Pattern Generator, Power Supply, Digital Voltmeter, Luminance meter (SR_3 or equivalent)
Aperture
1
with 50cm viewing distance
Test Point
Center
Environment < 1 lux
LCD Module
SR_3 or
equivalent
Measuring distance
Module Driving Equipment
G084SN03 V1 rev. 0.1
6/26