FRC1 RELAY
FEATURES
High contact rating (40A)
High temperature design
1 Form A and 1 Form C arrangements
Ideal for use in control-car starter and light
Quick connect or P.C. board terminals
Dust cover or sealed type
SPECIFICATIONS
COIL RATING
RATED
VOLTAGE
COIL
RESISTANCE
RATED
CURRENT
MUST OPERATE MUST DROPOUT
VOLTAGE VOLTAGE
MAXIMUM
VOLTAGE
POWER
CONSUMPTION
% OF RATED VOLTAGE (At +20 oC)
( V DC)
Ω +/− 10%
22.5
(mA)
267
133
67
(W)
6
12
24
90
65 Max.
10 Min.
130 Max.
1.6
360
CHARACTERISTICS
Contact Arrangement
Contact Material
1 Form A (SPST), 1 Form C (SPDT), 1 Form U (= 2 x 1 Form A)
Silver Alloy
Contact Resistance
50mΩ Max
N.O. : 40A 14VDC; N.C. : 30A 14VDC
For 1 Form U : 2 x 15A
DC 75V
Contact Rating (Resistive Load)
Switching Voltage
Operate Time (Initial)
Release Time (Initial)
Insulation Resistance
Dielectric Strength
Shock Resistance
Vibration Resistance
Ambient Temperature
Humidity
7ms Max.
5ms Max.
100MΩ Min.( 500V DC)
500Vrms between coil and contact
20g Approx.
10-40Hz, Double amplitude 1.5mm
-40oC to +85oC
20 - 85% RH
Mechanical : 107
Operation Life
Electrical
: 10 5
Weight
30g Approx.
[Specifications are subject to change without notices.]