4
F-Series Circuit Breaker – Ordering Scheme
F A 2 B 0 14 820 1 2 A B G
8
9
10
12
Agency
Approval
4
5
6
7
11
1
2
3
Terminal
Actuator Mounting
Color
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
Max. App.
Rating
Series
Actuator
Poles
12,13
1 SERIES
9 ACTUATOR COLOR & LEGEND
F
Actuator Color
White
I-O
A
ON-OFF
Dual
1
2
Marking Color
Black
White
B
D
Black
C
2 ACTUATOR
A
S
T
Handle, one per pole
Mid-Trip Handle, one per pole
Mid-Trip Handle, one per pole & Alarm Switch
10 MOUNTING
Front Mounting Inserts
Back Mounting Inserts
10-32 screw clearance holes
10-32 screw clearance holes
A
B
10-32
ISO M5
3 POLES
One
1
2
Two
3
Three
11 MAXIMUM APPLICATION RATING
VOLTAGE
125 VDC
120/240
CURRENT
700A
4 CIRCUIT
Parallel Pole Construction:
B
C
F
7
1
3,4
(
)
A
B
C
Switch Only no coil
M
N
P
Series Trip (Current) with Metering Shunt
Switch Only with Metering Shunt
Series Trip (Current)
15
16
250A
3,4
3
3
(
)
Series Trip current
Series Trip voltage
277 VAC
250A
250A
2
(
)
120/208 VAC
Q
Switch Only
12 AGENCY APPROVAL
5
5 AUXILIARY SWITCH
A
G
J
No approvals
0
2
3
4
without Auxiliary Switch
7
S.P.S.T. 0.110 Q.C. Terminals
(Gold Contacts)
S.P.S.T. 0.187 Q.C. Terminals
S.P.D.T. 0.187 Q.C. Terminals
S.P.S.T., 0.093 Round
QC Terminals
UL489 Listed & CUL Certified
S.P.D.T. 0.110 Q.C. Terminals
S.P.D.T. 0.139 Solder Lug
S.P.D.T. 0.110 Q.C. Terminals
(Gold Contacts)
UL489 Listed, CUL Certified & TUV Certified
8
9
A
T
UL489A (Telecom) Listed
6
6
Notes:
5
6
S.P.S.T., 0.093 Q.C. Terminals
(Gold Contacts)
S.P.S.T. 0.110 Q.C. Terminals
1
2
3
For 100 to 250 amps, select Current Code 825. For 300-400 amps, select Current
Code 840. For 450-700 amps, select Current Code 870.
B
S.P.D.T., 0.093 Round
QC Terminals
Available with Frequency and Delay code 10 or 20 only, and are not rated for continuous
duty. Delay 10 and 20 are only available with voltage coils.
3 Codes M, N, P & Q (Parallel Poles) are supplied with factory installed Bus Bar on
Line and Load.
6 FREQUENCY & DELAY
14
16
22
24
26
DC Medium
DC Long
AC Short
AC Medium
AC Long
4
5
4 Metering terminals are female pin type, ref. Molex part number 02-09-1101, model 1189-T.
Auxiliary Switch breakers are only available with Series Trip and Switch Only circuits.
On multi-pole breakers, one Auxiliary Switch is supplied, mounted in the extreme right
pole per figure A. Back-Mounted breakers require special mounting provisions when
an Auxiliary Switch is specified.
Available with parallel pole construction (circuit codes P and Q, and breakers with
circuit codes M and N).
Frequency and delay code 10 is only available with Voltage Coils. Voltage Coils are not
rated for continuous duty.
Ratings over 250 amps are only available with Agency Approval code T (UL489A) and
are Parallel Pole configuration (circuit codes M, N, P and Q.) 300-450 amp ratings are
available on two pole breakers. 500-700 amp ratings are available on three pole
breakers.
Per UL requirement, an “Anti-Flash Over Barrier” is supplied between poles on multipole
breakers with 3/8 - 16 stud terminals (Terminal Code 1) on AC rated breakers only.
03
10
11
12
DC 50/60Hz, Switch Only
DC Instantaneous
DC Ultra Short
7
DC Short
6
7
8
7 CURRENT RATING (AMPERES)
CODE AMPERES
8
8
8
8
8
810 100.000
912 125.00
815 150.00
917 175.00
820 200.00
922 225.00
825 250.00
835 350.00
860 600.00
8
840 400.00
870 700.00
845 450.00
9
8
830 300.00
850 500.00
10 Front connected breakers can also be front mounted by utilizing the supplied front panel
mounting inserts. Terminal connections must be made before mounting.
11 Box Wire connector will accept #6 through 250 MCM copper wire.
12 Agency codes G & T must have ON-OFF or dual legends. Agency code J must have
dual legend.
7
OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS)
CODE AMPERES
A06 6 DC, 5 DC
A12 12 DC, 10 DC
A18 18 DC, 15 DC
A24 24 DC, 20 DC
A32 32 DC, 25 DC
A48 48 DC, 40 DC
A65 65 DC, 55 DC
B25 125 DC, 100 DC
J06 6 AC, 5 AC
13 Other colors available. Consult factory.
14 Terminals 2,4 & 5 are shipped without terminal hardware.
15 2 or 3 Pole Circuit Breaker Required for 120/240 VAC Rating.
16 3 Pole Circuit Breaker Required for 120/208 VAC Rating.
8 TERMINAL
Back Connected (Front Mounted Only)
Max Rating
250A
9
14
14
1
2
5
3/8-16 Stud
3/8-16 Screw, Line & Load
3/8-16 Short Stud
700A
250A
11
Front Connected (Back Mounted Only)
Max Rating
700A
3
4
Box Wire Connector, Line & Load
3/8-16 Screw, Line & Load
14
700A
Email: sales@carlingtech.com Application Support: team2@carlingtech.com