F1100AA/F1150AA
(1, 3, 6, 10 and 20Amp) Dimensions
Specifications:
Rated Voltage: 250VAC Maximum - 50/60 Hz
Rated Current:
115VAC
1A
250VAC
1A
Amps
A
B
C
D
E
2A
3A
6A
10A
20A
30A
1.5A
2.5A
4A
6A
10A
15A
2.500
(63,5)
1.750
(44,5)
.625
(15,8)
2.125
(53,9)
1.425
(362)
1A
2.500
(63,5)
1.750
(44,5)
.750
(19,1)
2.125
(53,9)
1.8
(45,8)
3A
6A
2.500
(63,5)
1.750
(44,5)
.750
(19,1)
2.125
(53,9)
1.8
(45,8)
Current Overload: 6X for 8 seconds
2.500
(63,5)
1.750
(44,5)
1.125
(28,5)
2.125
(53,9)
1.8
(45,8)
10A
20A
Hi-Pot Test (1 min):
Line to Ground:
Line to Line:
F1100/F1150
1500VAC
1768VDC
F1199
1500VAC
1450VDC
2.760
(70,6)
2.000
(60,8)
1.125
(28,5)
2.375
(60,3)
2.550
(64,8)
Insulation Resistance: 9 x 109 Ω at 100VDC
Ambient Temperature: 40°C Max. at rated current
Humidity Range: 0% to 95% R.H.
Termination:
.188 Dia.
(4,77) 2 Holes
B
L
I
N
E
L
A
A: QC – Quick Connect
B: Wire
D: Screw
P: PCB Mount
O
A
D
D
Maximum Leakage Current:
Each Line to Ground
115VAC, 60Hz:
F1100
0.40mA
.75mA
F1150
0.25mA
0.40mA
F1199
0.25mA
0.45mA
250VAC, 50Hz:
E
Agency Approvals:
C
.250 Q.C.
(6.4)
F1100
F1500
F1199
F1100
F1100
F1150
F1199
Except 20Amp
F1150
F1199
F1100BB/FB1150BB
(1, 3, 6 and 10Amp) Dimensions
F1199
Amps
A
B
C
D
E
2.500
(63,5)
1.750
(44,5)
.625
(15,8)
2.125
(53,9)
.875
(22,2)
F1100DD/F1150DD
(20Amp Only) Dimensions
1A
2.500
(63,5)
1.750
(44,5)
.750
(19,1)
2.125
(53,9)
1.250
(31,8)
3A
6A
.188 Dia.
(4,77) 2 Holes
2.500
(63,5)
1.750
(44,5)
.750
(19,1)
2.125
(53,9)
1.250
(31,8)
2.500
(63,5)
1.750
(44,5)
1.125
(28,5)
2.125
(53,9)
1.250
(31,8)
10A
L
L
O
A
D
2.760
(70,6)
2.000
I
(50,8)
.188 Dia.
(4,77) 2 Holes
N
E
2.375
(60,3)
L
I
N
E
L
A
O
A
D
B
D
(5) No. 8-32
.625
(15,8)
2.000
(50,8)
.625
(15,8)
Studs
1.125
(25,5)
4.000
(101,6)
Min.
E
.250±.062
(6,35) Typ.
C
No. 18 Gauge Wire
Dimensions are in inches and millimeters
unless otherwise specified.
Values in parentheses are metric equivalents.
5
Curtis Industries
1-800-657-0853
A Division of Powers Holdings, Inc.