F0110 Datasheet
2. Specifications
2.1
Absolute Maximum Ratings
The absolute maximum ratings are stress ratings only. Stresses greater than those listed below can cause
permanent damage to the device. Functional operation of the F0110 at absolute maximum ratings is not implied.
Exposure to absolute maximum rating conditions can affect device reliability.
Parameter
Symbol
VCC
Minimum
-0.3
Maximum
+ 6.0
Unit
V
VCC to GND
STBY1, STBY2
VCTL
-0.3
+5.25
V
RFIN1, RFIN2 externally applied DC voltage
VRFIN
- 0.3
+ 0.3
V
RFOUT1, RFOUT2 externally applied DC voltage
VRFOUT
- 0.3
+ 6.0
V
ON STATE: RF CW Input Power (RFIN1, RFIN2) applied for 2 hours max.
VCC = 5V, TEP = 105˚C, input / output VSWR < 2:1 based on a 50Ω system. [a]
PMAX_IN_ON
22
22
dBm
dBm
OFF STATE: RF CW Input Power (RFIN1, RFIN2) applied for 2 hours max.
VCC = 5V, TEP = 105˚C, input / output VSWR < 2:1 based on a 50Ω system. [a]
PMAX_IN_OFF
TSTOR
TLEAD
VESDHBM
VESDCDM
Storage Temperature Range
-65
+150
+260
500
°C
°C
V
Lead Temperature (soldering, 10s)
Electrostatic Discharge – HBM (JEDEC/ESDA JS-001-2012)
Electrostatic Discharge – CDM (JEDEC 22-C101F)
500
V
[a] Exposure to these maximum RF levels can result in significantly higher ICC current draw due to overdriving the amplifier stages.
2.2
Recommended Operating Conditions
Typical
Maximum
Unit
Parameter
Symbol
VCC
Condition
Minimum
4.75
Power Supply Voltage [a]
Operating Temperature Range
Junction Temperature
5.25
+105
+160
2300
V
°C
Exposed paddle
TEP
-40
TJ
°C
RF Frequency Range
FRF
1500
MHz
Maximum Operating RF Input
Power to RFIN1, RFIN2 [b]
PMAX
+5
dBm
RF Source Impedances
RF Load Impedances
Single-ended
Single-ended
ZRFI
50
50
Ω
Ω
ZRFO
[a] Functional voltage operating range. Device is designed to function with any supply voltage ≥ 4.75V, although performance may be
degraded when operated outside the recommended voltage range.
[b] CW power over operating temperature, operating voltage and operating frequency range. Input / output VSWR < 2:1.
R35DS0015EU0104 Rev.1.04