APPLICABLE STANDARD
Note deleted
2
Operating Temperature
Range
Storage Temperature
Range
-25°C to +105°C(2)
-10°C to +60°C
Voltage
AC 1000V , DC 1500V
Rating
60mm2(AWG1/0)
100mm2 (AWG4/0)
175A (60mm2 cable)
240A (100mm2 cable)
Current
Applicable Cable
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Marking
Examined visually and with a measuring instrument.
Confirmed visually.
X
X
X
X
According to the drawing.
ELECTRICAL CHARACTERISTICS
Contact Resistance
X
X
Measured at DC 1A.
0.1mΩ MAX.
―
Insulation Resistance
Voltage Proof
Measured at DC 500V.
1000MΩ MIN.
―
AC 5000V applied for 1min.
(JIS C 8201)
Measured at 7200A applied for 1s. (60mm2 cable)
No flashover or breakdown.
X
X
―
―
Short-Time Withstand
Current Test
Measured at 12000A applied for 1s. (100mm2 cable) Contact Resistance: 0.15 mΩ MAX.
(JIS C 8201)
MECHANICAL CHARACTERISTICS
Crimp Contact Insertion
Insertion Force: 280N MAX.
Extraction Force: 250N MAX.
Measured with an applicable connector.
X
X
―
―
and Extraction Forces
1) No function impairing damage, cracks, or
looseness of parts.
2) Contact Resistance: 0.15mΩ MAX.
3) Insertion Force: 280N MAX.
4) Extraction Force: 250N MAX.
Contact Inserted and Extracted 50 times.
Mechanical Operation
Frequency: 10 Hz to 55 Hz
Single amplitude: 0.75 mm
Performed two hours in each of three mutually
perpendicular directions.
(MIL-STD-1344 Method 2005, Condition 2)
Acceleration: 500 m/s2
Half sine wave pulses of 11 ms.
Performed five times both ways in each of three
mutually perpendicular directions.
1) No electrical disconuity of 10μs.
2) No damage, cracks, or looseness of parts.
Vibration
Shock
1
X
―
1) No electrical disconuity of 10μs.
2) No damage, cracks, or looseness of parts.
X
X
―
―
250 N (60mm2 cable)
351 N (100mm2 cable)
Contact Retention Force
No damage.
A pulling force was applied to the connection side.
(NECA C 2811)
ENVIRONMENTAL CHARACTERISTICS
1) Insulation Resistance: 20MΩ MIN.
2) Voltage Proof: AC 5000V applied for 1min.
No flashover or breakdown.
3) No damage, cracks, or looseness of parts.
1) Insulation Resistance: 20MΩ MIN.
2) Voltage Proof: AC 5000V applied for 1min.
No flashover or breakdown.
Subjected to 40±2°C, at a humidity 90% to 95%, for
96 hours. Returned to room temperature and normal
humidity, and removed of any water. (NECA C 2811)
Damp Heat
(Steady State)
X
X
―
―
Subjected to -25±3°C for 2 hours. Returned to room
Heat and Cold Resistance temperature for 1 hour. Subjected to 70±3°C for 2
hours . (NECA C 2811)
3) No damage, cracks, or looseness of parts.
175A (60mm2 cable)
240A (100mm2 cable)
1) Contact Resistance: 0.15mΩ MAX.
2) No damage, cracks, or looseness of parts.
With the rated current shown above applied,
Ageing Test
X
―
subjected to the following cycle 192 times.
Subjected to 40±3°C for 10 minutes, cooled to 30°C
and left for 10 minutes. (JIS C 8201)
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
HR.SATO
CHECKED
DATE
2
1
DIS-C-00017593
KI.NAGANUMA
20240520
Notes
Above specifications show the values in assembled condition with
applicable crimp contacts.
(1)
APPROVED
YH.YAMADA
20190521
CHECKED
DESIGNED
DRAWN
TP.KOMATSU
EK.KIDO
20190521
20190521
20190521
(2) Including temperature rise caused by current carrying.
Unless otherwise specified, refer to IEC 60512 (JIS C 5402).
EK.KIDO
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-387455-00-00
EF2A-DH200B-1
SPECIFICATION SHEET
2
1/1
HIROSE ELECTRIC CO., LTD.
△
CL0142-0229-0-00
FORM HD0011-2-1